--- Page 1 ---
Troubleshooting Manual


   Models
    T350
   T500J
      3121203
   September 7, 2005

--- Page 3 ---
INTRODUCTION


A.7 SERVICE FAULT CODE CROSS REFERENCES
CODE - MESSAGE                                                                                                                                                                PAGE NO.
0
0 Chassis Tilt Sensor Out Of Range ..............................................................................................................................................2-46
0 Engine Not Running ...................................................................................................................................................................2-60
0 Joystick Moved But Trigger Switch Open .................................................................................................................................2-85
0 Running At Creep - Material Hook Mode ................................................................................................................................2-104
0 Running At Creep - Tilted & Above Elevation ........................................................................................................................2-104
0 Running At Creep - Unset & Above Elevation ........................................................................................................................2-104
2-?
2-1 Keyswitch Faulty ....................................................................................................................................................................2-86
2-1 Platform Position Detection Faulty .........................................................................................................................................2-97
2-2 Function Locked Out - Joystick Not Centered At Startup ......................................................................................................2-65
2-2 Function Locked Out - Trigger Permanently Closed ..............................................................................................................2-66
2-2 Function Problem - Engine Choke Permanently Selected ......................................................................................................2-66
2-2 Function Problem - Engine Start Permanently Selected .........................................................................................................2-67
2-2 Function Problem - Rotary Selector Switch ............................................................................................................................2-74
2-2 Joystick Faulty - X axis Wiper Out Of Range ........................................................................................................................2-83
2-2 Joystick Faulty - Y axis Wiper Out Of Range ........................................................................................................................2-84
2-2 Trigger Closed Too Long While In Neutral ..........................................................................................................................2-116
2-3 Function Problem - Engine Choke Permanently Selected ......................................................................................................2-67
2-3 Function Problem - Engine Start Permanently Selected .........................................................................................................2-68
2-3 Function Problem - Jib Down Permanently Selected .............................................................................................................2-68
2-3 Function Problem - Jib Up And Down Both Selected ............................................................................................................2-69
2-3 Function Problem - Jib Up Permanently Selected ..................................................................................................................2-69
2-3 Function Problem - Level Down Permanently Selected .........................................................................................................2-70
2-3 Function Problem - Level Up And Down Both Selected ........................................................................................................2-70
2-3 Function Problem - Level Up Permanently Selected ..............................................................................................................2-71
2-3 Function Problem - Lift Down Permanently Selected ............................................................................................................2-71
2-3 Function Problem - Lift Up And Down Both Selected ...........................................................................................................2-72
2-3 Function Problem - Lift Up Permanently Selected .................................................................................................................2-72
2-3 Function Problem - Outrigger Set And Stow Both Selected ...................................................................................................2-73
2-3 Function Problem - Outrigger Set Permanently Selected .......................................................................................................2-73
2-3 Function Problem - Outrigger Stow Permanently Selected ....................................................................................................2-74
2-3 Function Problem - Swing Left And Right Both Selected ......................................................................................................2-75
2-3 Function Problem - Swing Left Permanently Selected ...........................................................................................................2-76
2-3 Function Problem - Swing Right Permanently Selected .........................................................................................................2-76
2-3 Function Problem - Telescope In And Out Both Selected ......................................................................................................2-77
2-3 Function Problem - Telescope In Permanently Selected ........................................................................................................2-77
2-3 Function Problem - Telescope Out Permanently Selected ......................................................................................................2-78
2-5 Drive & O/R Prevented - Operate From Platform ..................................................................................................................2-50
2-5 Drive & O/R Prevented - Place Boom On Rest ......................................................................................................................2-51
2-5 Drive & O/R Prevented - Set Hand Brake ..............................................................................................................................2-51
2-5 Drive Prevented - Lift Down ...................................................................................................................................................2-55
2-5 Drive Prevented - Stow Outriggers .........................................................................................................................................2-55
2-5 Drive Prevented - Telescope In ...............................................................................................................................................2-55
2-5 Lift Down Prevented - Tele In First ........................................................................................................................................2-90
2-5 Lift Up & Tele Out Prevented - Tilted & Above Elevation ....................................................................................................2-91
2-5 Lift Up & Tele Out Prevented - Tilted,Unset,& Above Elevation .........................................................................................2-92
2-5 Lift Up & Tele Out Prevented - Unset & Above Elevation ....................................................................................................2-92
2-5 Lift Up Prevented - Check Outriggers ....................................................................................................................................2-92
2-5 Lift Up Prevented - Lift Down Then Set Outriggers ..............................................................................................................2-93
2-5 Lift Up Prevented - Tilted .......................................................................................................................................................2-93
2-5 Model Changed - Hydraulics Suspended - Cycle EMS ..........................................................................................................2-95
2-5 Outrigger Stow Prevented - Tele In First ................................................................................................................................2-97
2-5 Outriggers Prevented - Elevated .............................................................................................................................................2-97


3121203                                                                                    T350 T500J                                                                                           A-11

--- Page 4 ---
TABLE OF CONTENTS


      2.65    Function Problem - Level Up Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-71
      2.66    Function Problem - Lift Down Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-71
      2.67    Function Problem - Lift Up And Down Both Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-72
      2.68    Function Problem - Lift Up Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-72
      2.69    Function Problem - Outrigger Set And Stow Both Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-73
      2.70    Function Problem - Outrigger Set Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-73
      2.71    Function Problem - Outrigger Stow Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-74
      2.72    Function Problem - Rotary Selector Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-74
      2.73    Function Problem - Swing Left And Right Both Selected. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-75
      2.74    Function Problem - Swing Left Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-76
      2.75    Function Problem - Swing Right Permanently Selected. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-76
      2.76    Function Problem - Telescope In And Out Both Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-77
      2.77    Function Problem - Telescope In Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-77
      2.78    Function Problem - Telescope Out Permanently Selected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-78
      2.79    Functions At Cutback - Power Module Current Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-78
      2.80    Functions Locked Out - Constant Data Version Improper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-78
      2.81    Functions Locked Out - Platform Module Software Version Improper. . . . . . . . . . . . . . . . . . . . . .2-78
      2.82    Functions Locked Out - Power Module Software Version Improper . . . . . . . . . . . . . . . . . . . . . . .2-79
      2.83    Ground Alarm Short To Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-79
      2.84    Ground Alarm Short To Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-79
      2.85    Ground Module Failure: Ref Voltage Out Of Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-80
      2.86    Ground Module Failure: Vlow Fet Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-80
      2.87    Hourmeter Short To Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-80
      2.88    Jib Down Solenoid Open Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-80
      2.89    Jib Down Solenoid Short To Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-81
      2.90    Jib Down Solenoid Short To Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-81
      2.91    Jib Up Solenoid Open Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-82
      2.92    Jib Up Solenoid Short To Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-82
      2.93    Jib Up Solenoid Short To Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-83
      2.94    Joystick Faulty - X axis Wiper Out Of Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-83
      2.95    Joystick Faulty - Y axis Wiper Out Of Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-84
      2.96    Joystick Moved But Trigger Switch Open. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-85
      2.97    Keyswitch Faulty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-86
      2.98    Level Down Solenoid Open Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-87
      2.99    Level Down Solenoid Short To Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-87
      2.100   Level Down Solenoid Short To Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-88
      2.101   Level Up Solenoid Open Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-88
      2.102   Level Up Solenoid Short To Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-89
      2.103   Level Up Solenoid Short To Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-89
      2.104   Lift Down Prevented - Tele In First . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-90
      2.105   Lift Down Solenoid Open Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-90
      2.106   Lift Down Solenoid Short To Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-91
      2.107   Lift Down Solenoid Short To Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-91
      2.108   Lift Up & Tele Out Prevented - Tilted & Above Elevation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-91
      2.109   Lift Up & Tele Out Prevented - Tilted,Unset,& Above Elevation . . . . . . . . . . . . . . . . . . . . . . . . . . .2-92
      2.110   Lift Up & Tele Out Prevented - Unset & Above Elevation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-92
      2.111   Lift Up Prevented - Check Outriggers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-92
      2.112   Lift Up Prevented - Lift Down Then Set Outriggers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-93
      2.113   Lift Up Prevented - Tilted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-93
      2.114   Lift Up Solenoid Open Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-94
      2.115   Lift Up Solenoid Short To Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-94
      2.116   Lift Up Solenoid Short To Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-95
      2.117   Model Changed - Hydraulics Suspended - Cycle EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-95
      2.118   No Charge System Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-95
      2.119   Open-Circuit Pump Motor Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-96
      2.120   Optional Ground Alarm Short To Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-96
      2.121   Optional Ground Alarm Short To Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-96
      2.122   Outrigger Stow Prevented - Tele In First. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-97


3121203                                                            T350 T500J                                                                                      21

--- Page 5 ---
SECTION 1 - TROUBLESHOOTING BY FUNCTION


1.5 BATTERY CHARGER NOT FUNCTIONING PROPERLY
    Delta-Q Charger Normal Operation Description
         Stage                                                                 Description
     Startup       The charger will automatically turn on and go through a short self-test with the LED indicator alternating red-green for two sec-
                   onds. If the charger is connected to a battery pack, a trickle current will be applied until a minimum voltage is reached. If the
                   charger is used in an off-board application and the charger is waiting to be plugged into a battery pack, the charging algorithm
                   number will be displayed for 11 seconds before ultimately displaying an under-voltage fault (fault disappears when plugged
                   into battery pack). Typically lasts from 5 seconds to 2 ½ minutes.
     Bulk          Typically, 80% of the total recharge is restored during the bulk phase where a constant 25 Amp output is being delivered. This
                   time varies depending upon the depth of discharge.
     Absorption    Output reduced to prevent sulfation build up. Time depends upon the initial level of battery charge and varies from 1hour mini-
                   mum to 5 ½ hours. At completion of this phase, 90% charge has been obtained.
     Finish        Delivers 6A for at least 1 hour to finish charge.

 There will be a cut back in output any time the charger is below 108 VAC. ANY interruption where there is power loss causes
 the charger to reset. If left plugged in, the charger will restart in 30 days or when the Voltage drops
                                  Battery Charge Level and Normal Charging Time
                                     Number of
                                                         Battery Charge Level           Recharge time (hours)
                                      Cycles
                                         15                  75% (24.8V)                           12
                                         30                  50% (24.2V)                          13.1
                                         50                  20% (23.4V)                          14.7
                                         66            0% (less than 23.2V)                        15


Step Pretest Instructions                              Test                             Result                         Corrective Action
 1.5.1                                    Does charger go through            Yes                               Go to step 1.5.2
                                          proper LED sequencing upon         No                                Check AC power supply.
                                          start up?
 1.5.2                                    Is the red LED on?                 Yes                               Possible Causes: 4.1.1, 4.1.3, 4.1.4
                                                                             No                                Do some function to cause draw on the
                                                                                                               battery, then start again. Otherwise, go to
                                                                                                               step 1.5.3
 1.5.3 Check the voltage on each bat- Do all batteries have at least         Yes                               Go to step 1.5.4
       tery. 25% - 6.12 V, 100% =     6.12V?                                 No                                Possible Causes: 4.1.4
       6.32 V
 1.5.4 Using a hydrometer - Check         Is the specific gravity of all bat- Yes                              Possible Causes: 4.1.8
       the specific gravity in each       tery cells between 1.155 and No                                      Possible Causes: 4.1.4
       battery cell. 25% charged is       1.265?
       1.155, 100% = 1.265


3121203                                                                T350 T500J                                                                      1-31

--- Page 6 ---
SECTION 2 - TROUBLESHOOTING BY FAULT MESSAGES


                         SECTION 2. TROUBLESHOOTING BY FAULT MESSAGES

2.1 ACCESSORY FAULT
Distress Lamp: 9              ADE Code: 6-7
  An attached accessory is communicating a fault to the ground control.

 Step     Pretest Instructions                 Test                       Result                Corrective Action
  2.1.1                             Is an accessory installed?   Yes                      Refer to Information Supplied with
                                                                                          Accessory
                                                                 No                       Possible Causes: 4.1.2


2.2 BATTERY VOLTAGE TOO HIGH - SYSTEM SHUTDOWN
Distress Lamp: 3              ADE Code: 4-4
  The system detected a battery voltage above 36 Volts for an electric powered machine.
  ELECTRIC POWERED MACHINES ONLY
  Functions Disabled (Electric Powered Machines Only): Lift Up, Lift Down, Swing Left, Swing Right, Telescope In, Telescope
  Out, Jib Up, Jib Down, Level Up, Level Down, Front Left O/R, Front Right O/R, Rear Left O/R, Rear Right O/R, Set (Extend O/
  R), Stow (Retract O/R), Drive
  Possible Causes: 4.1.2, 4.1.3, 4.1.4


2.3 BATTERY VOLTAGE TOO HIGH - SYSTEM SHUTDOWN
Distress Lamp: 5              ADE Code: 4-4
  The system detected a battery voltage above 18 Volts for an engine powered machine.
  ENGINE POWERED MACHINES ONLY
  Functions Disabled (Engine Powered Machines Only): Lift Up, Lift Down, Swing Left, Swing Right, Telescope In, Telescope
  Out, Jib Up, Jib Down, Level Up, Level Down, Front Left O/R, Front Right O/R, Rear Left O/R, Rear Right O/R, Set (Extend O/
  R), Stow (Retract O/R), Engine Start, Engine Throttle Pull, Engine Throttle Hold, Engine Choke Pull, Engine Choke Hold,
  Drive
  Possible Causes: 4.1.2, 4.1.3, 4.1.4


2.4 BATTERY VOLTAGE TOO LOW - SYSTEM SHUTDOWN
Distress Lamp: 3              ADE Code: 4-4
  The system detected a battery voltage below 16 Volts for an electric powered machine.
  ELECTRIC POWERED MACHINES ONLY
  Functions Disabled (Electric Powered Machines Only): Lift Up, Lift Down, Swing Left, Swing Right, Telescope In, Telescope
  Out, Jib Up, Jib Down, Level Up, Level Down, Front Left O/R, Front Right O/R, Rear Left O/R, Rear Right O/R, Set (Extend O/
  R), Stow (Retract O/R), Drive
  Possible Causes: 4.1.2, 4.1.3, 4.1.4


3121203                                                      T350 T500J                                                        2-41

--- Page 7 ---
SECTION 2 - TROUBLESHOOTING BY FAULT MESSAGES


2.21 DRIVE & O/R PREVENTED - PLACE BOOM ON REST
Distress Lamp: 2                      ADE Code: 2-5
  In Platform Mode, an attempt was made to operate Drive or Outriggers but the Boom was not detected by the Turntable posi-
  tion sensor at X073, or an error was detected with the sensor. When the boom is against the rest, TURNTABLE1 input,
  X074.3 = +B and TURNTABLE2 input, X074.4 = 0V. This could be caused by the boom not being properly stowed on the
  rest, an obstruction over the switch, the switch adjusted too far from the boom (should be within 0.188" of the boom), or a faulty
  transport limit switch or turntable position switch. If an error has been detected, the switch must be reset before drive will function.
  DRIVE OPTION MACHINES ONLY
  Functions Disabled (Drive Option Machines Only): Drive
  See 3.5 Drive Sensor Reset


2.22 DRIVE & O/R PREVENTED - SET HAND BRAKE
Distress Lamp: 2                        ADE Code: 2-5
  In Platform Mode, an attempt was made to operate Drive or Outriggers but the Hand Brake was not detected by the hand
  brake position sensor at X072 as set (applied) or an error was detected with the sensor. If the hand brake appears to be in
  the proper position, examine the Hand Brake Sensor wiring and adjustment. When the hand brake is applied, BRAKE1 input,
  X074.5 = +B and BRAKE2 input, X074.6 = 0V.This could be caused by the brake linkage or cable not being properly
  adjusted, an obstruction over the switch, the switch adjusted too far from the cylinder (should be within 0.188" of the extended
  cylinder), or a faulty switch. If an error has been detected, the switch must be reset before drive will function.
  DRIVE OPTION MACHINES ONLY
  Functions Disabled (Drive Option Machines Only): Drive
  See 3.5 Drive Sensor Reset


2.23 DRIVE ENABLE SOLENOID SHORT TO BATTERY
Distress Lamp: 9            ADE Code: 3-3
  Drive module feedback shows that the Drive Enable Valve PWM output may be shorted to battery or the solenoid may be
  defective
  DRIVE OPTION MACHINES ONLY
  Functions Disabled (Drive Option Machines Only): Drive

 Step     Pretest Instructions                    Test                          Result                     Corrective Action
 2.23.1 Run system test               Do other functions fail sys-   Yes                             Possible Cause: Black ground wire
                                      tem test?                                                      broken, 4.1.1, otherwise go to step
                                                                                                     2.23.2
                                                                     No                              Go to step 2.23.2
 2.23.2 Disconnect solenoid at        Rerun System Test              Analyzer Message “DRV ENABLE Replace solenoid
        X071and isolate wires                                        SHORT TO GROUND OR OPEN
                                                                     CIRCUIT“
                                                                     Analyzer Message “DRV ENABLE Go to step 2.23.3
                                                                     VALVE SHORT TO BATTERY“
 2.23.3 Remove wire Orn 55-1 from     Rerun System Test              Analyzer Message “DRV ENABLE Wire Orn 55-1 shorted to battery.
        X074.11                                                      SHORT TO GROUND OR OPEN      Repair or replace
                                                                     CIRCUIT“
                                                                     Analyzer Message “DRV ENABLE Possible Cause: 4.1.10
                                                                     VALVE SHORT TO BATTERY“


3121203                                                         T350 T500J                                                                 2-51

--- Page 8 ---
SECTION 2 - TROUBLESHOOTING BY FAULT MESSAGES


2.45 EXTEND O/R SOLENOID OPEN CIRCUIT
Distress Lamp: 9           ADE Code: 3-3
  Ground module feedback shows that Extend Outrigger digital output may be disconnected from the relay or the relay may
  be defective.
  Functions Disabled: Set (Extend O/R)

 Step     Pretest Instructions                      Test                          Result                  Corrective Action
 2.45.1 Run system test                 Do other functions fail sys-   Yes                         Possible Cause: Black ground wire
                                        tem test?                                                  broken, 4.1.1, otherwise
                                                                                                   Go to step 2.45.2
                                                                       No                          Go to step 2.45.2
 2.45.2 Disconnect solenoid at X086.    Rerun System Test              Analyzer Message “EXTEND    Replace solenoid and/or connector
        Short X086.1.soc to                                            VALVE SHORT TO GROUND“
        X086.2.soc                                                     Analyzer Message “EXTEND    Go to step 2.45.3
                                                                       VALVE OPEN CIRCUIT“
 2.45.3 Replace X003.13 with a          Rerun System Test              Analyzer Message “EXTEND    Wire Orn/Wht 55-3-1 or Orn/Wht 55-3
        jumper to X003.3                                               VALVE SHORT TO GROUND“      broken. Repair or replace
                                                                       Analyzer Message “EXTEND    Possible Cause: 4.1.10
                                                                       VALVE OPEN CIRCUIT“


2.46 EXTEND O/R SOLENOID SHORT TO BATTERY
Distress Lamp: 9           ADE Code: 3-3
  Ground module feedback shows that the Extend Outrigger Valve digital output may be shorted to battery or the solenoid
  may be defective.
  Functions Disabled: Set (Extend O/R)

 Step     Pretest Instructions                     Test                          Result                 Corrective Action
 2.46.1 Run system test                Do other functions fail sys-    Yes                        Possible Cause: Black ground wire
                                       tem test?                                                  broken, 4.1.1, otherwise go to step
                                                                                                  2.46.2
                                                                       No                         Go to step 2.46.2
 2.46.2 Disconnect solenoid at X086    Rerun System Test               Analyzer Message “EXTEND   Replace solenoid
        and isolate wires                                              VALVE OPEN CIRCUIT“
                                                                       Analyzer Message “EXTEND   Go to step 2.46.3
                                                                       VALVE SHORT TO BATTERY“
 2.46.3 Remove wire Orn/Wht 55-3-1 Rerun System Test                   Analyzer Message “EXTEND   Wire Orn/Wht 55-3-1 or Orn/Wht 55-3
        from X003.13                                                   VALVE OPEN CIRCUIT“        shorted to battery. Repair or replace
                                                                       Analyzer Message “EXTEND   Possible Cause: 4.1.10
                                                                       VALVE SHORT TO BATTERY“


3121203                                                          T350 T500J                                                             2-61

--- Page 9 ---
SECTION 2 - TROUBLESHOOTING BY FAULT MESSAGES


2.65 FUNCTION PROBLEM - LEVEL UP PERMANENTLY SELECTED
Distress Lamp: 1                  ADE Code: 2-3
  The ground level up switch was closed when the machine was powered. The switch could be accidentally held, mechani-
  cally stuck, or electrically shorted.

  Functions Disabled at Ground Only: Level Up

 Step     Pretest Instructions                     Test                        Result          Corrective Action
 2.65.1                                 Is the switch mechanically     Yes              Repair or replace the switch
                                        stuck?                         No               Go to step 2.65.2
 2.65.2 Disconnect X034. Place key      Is fault “Function Problem -   Yes              Go to step 2.65.3
        switch in ground position and   Level Up Permanently           No               Possible Causes: 4.1.18
        pull the emergency stop         Selected“still present?
        switch.
 2.65.3 Remove X014.27.pin from         Is fault “Function Problem -   Yes              Go to step 2.65.4
        X014. Place key switch in       Level Up Permanently           No               Possible Causes: Short in Pink 25-2
        ground position and pull the    Selected“still present?                         wire
        emergency stop switch.
 2.65.4 Place key switch in ground      Measured voltage at            Yes              Possible Causes: Short in Pink 25-2-1
        position and pull the emer-     X004.17 = Vbatt?                                wire, 4.1.10
        gency stop switch.                                             No               Possible Causes: 4.1.10


2.66 FUNCTION PROBLEM - LIFT DOWN PERMANENTLY SELECTED
Distress Lamp: 1                  ADE Code: 2-3
  The ground lift down switch was closed when the machine was powered. The switch could be accidentally held, mechani-
  cally stuck, or electrically shorted.

  Functions Disabled at Ground Only: Lift Down

 Step     Pretest Instructions                     Test                        Result          Corrective Action
 2.66.1                                 Is the switch mechanically     Yes              Repair or replace the switch
                                        stuck?                         No               Go to step 2.66.2
 2.66.2 Disconnect X031. Place key      Is fault “Function Problem -   Yes              Go to step 2.66.3