PDF Shop Manual Komatsu PC290LC-11 Hydraulic Excavator - 4 MB
This is the official shop manual for the Komatsu PC290LC-11 Hydraulic Excavator, an essential resource for any technician or owner.
It provides comprehensive, step-by-step instructions for all repair and maintenance procedures.
With detailed diagrams and specifications, you can confidently tackle everything from simple adjustments to complete engine overhauls.
Keep your powerful PC290LC-11 operating at peak efficiency and reduce costly downtime.
This manual is the key to professional-level service.
PDF Viewer
Viewer loads when you scroll here
SHARE THIS MANUAL
Download the PDF Manual
PDF viewer loading area
Text Preview from This Manual
The text below was extracted from the visible preview pages to help you confirm the manual contents before download.
--- Page 1 ---
SEN06507-20
HYDRAULIC PC290LC -11
EXCAVATOR SERIAL NUMBERS 35001 and up
--- Page 3 ---
Safety Notice for Operation 00 Index and Foreword
Precautions During Work
• For the machine with the battery disconnect switch, check before starting the work that the system operat-
ing lamp is not lit. Then, turn the battery disconnect switch to OFF (○) position.
REMARK
Remove the key after it is turned to OFF (○) position if the battery disconnect switch is a switch key type.
For the machine without the battery disconnect switch, turn the starting switch to OFF position, wait for two
minutes or more before starting the work. Disconnect the battery cable by starting from the negative (-) ter-
minal first.
• For the machine with the quick release battery terminal (-), check before starting the work that the system
operating lamp is not lit. Then, disconnect the quick release battery terminal (-).
REMARK
For the machine without the system operating lamp, turn the starting switch to OFF position, wait for two
minutes or more before starting the work. Disconnect the quick release battery terminal (-).
• Release the remaining pressure from the circuit before starting the work of disconnecting and removing of
oil, fuel, water, or air from the circuit. When removing the cap of oil filter, drain plug, or oil pressure plug, it
should be done slowly otherwise the oil spills.
• When removing or installing the checking plug or the piping in the fuel circuit, wait 30 seconds or longer
after the engine is shut down and start the work after the remaining pressure is released from the fuel cir-
cuit.
• The coolant and oil in the circuits are hot when the engine
is shut down. Be careful not to get scalded. Wait for the oil
and coolant to cool before performing any work on the oil
or coolant circuits.
00-26 PC290LC-11
--- Page 4 ---
00 Index and Foreword Practical Use of KOMTRAX
Practical Use of KOMTRAX
Various information which KOMTRAX system transmits by using the radio communication is useful for KOM-
TRAX operator to provide various services for the customers.
When KOMTRAX system is installed to the machine and it is enabled, machine information can be checked by
KOMTRAX system, and it is used for testing and troubleshooting to be performed efficiently.
Large-sized models are equipped with KOMTRAX Plus which can use more detailed information.
REMARK
(KOMTRAX may not be installed to the machine in some countries or areas.)
Advantage to Use KOMTRAX
• The location where the machine is working at can be checked on the map in a personal computer.
• Operation information such as service meter, operating hours, fuel consumption, and occurred caution as
well as failure code can be checked.
• The operator can check the hours used and replacement interval of consumable parts of the machine such
as fuel filter, hydraulic oil filter, hydraulic oil and engine oil.
• Information of how machine is operated (idling time, traveling time, digging time, relieving time, etc.) can be
checked, and it is used to presume the machine operating condition.
• Various reports such as “Fuel saving operation support”, “Operation summary”, etc. is generated, and it is
utilized as an advice tool for the user and operator.
• KOMTRAX Plus can record the data of abnormality record, trend data, snap shot data, etc. to grasp the
soundness of machine, in addition to KOMTRAX function described above. These data can be used on per-
sonal computer screens.
How to Make a Full Use of KOMTRAX
Making use of KOMTRAX enables the following activities.
• Quick response to a request for immediate repair
1. To check the displayed caution and failure code, etc. through KOMTRAX upon receiving a repair re-
quest from a user.
2. To immediately arrange necessary tools, replacement parts, etc, immediately in accordance with the
displayed failure code.
3. To find the location of the failed machine by using the map of KOMTRAX, to visit the customer there.
• Proactive maintenance
1. To check the service summary screen of KOMTRAX, to find the machine which has high priority failure
code indicated by a red or yellow flag.
2. To check the condition of the machine with the customer and to make a plan to visit.
3. To immediately arrange necessary tools, replacement parts, etc, immediately in accordance with the
displayed failure code.
• Practice of periodic maintenance and periodic inspection service
1. To check the service summary screen of KOMTRAX, and to find the machine of which the usage limits
for the consumable parts indicated by red flags are over.
2. To submit an estimate sheet for the consumable parts to be replaced and the labor cost for the replace-
ment work to the customer.
3. To propose the periodic inspection (Pm clinic, etc.) according to the service meter reading.
How to Operate KOMTRAX
For the operating method of each screen of KOMTRAX, ask KOMTRAX key person in your Komatsu distributor.
PC290LC-11 00-53
--- Page 5 ---
Standard Tightening Torque Table 00 Index and Foreword
Thread diam- Width across Tightening torque (Nm {kgfm} )
Nominal No.
eter (mm) flats (mm) Range Target
18 18 27 34.3 to 44.1 {3.5 to 4.5} 39.2 {4.0}
20 20 30 44.1 to 53.9 {4.5 to 5.5} 49.0 {5.0}
24 24 32 58.8 to 78.4 {6.0 to 8.0} 68.6 {7.0}
30 30 32 93.1 to 122.5 {9.5 to 12.5} 107.8 {11.0}
33 33 - 107.8 to 147.0 {11.0 to 15.0} 127.4 {13.0}
36 36 36 127.4 to 176.4 {13.0 to 18.0} 151.9 {15.5}
42 42 - 181.3 to 240.1 {18.5 to 24.5} 210.7 {21.5}
52 52 - 274.4 to 367.5 {28.0 to 37.5} 323.4 {33.0}
Table of Tightening Torque for Hose (Taper Seal Type and Face Seal Type)
REMARK
• Tighten the hose fittings (taper seal type and face seal type) to the torque shown in the following table un-
less otherwise specified.
• The table is applied to the threaded portion coated with engine oil (wet threaded portion).
Width Tightening torque (Nm {kgfm} ) Taper seal Face seal
Nominal
across Nominal size - Thread root
No. of Thread size
flats Range Target threads per diameter(mm)
hose (mm)
(mm) inch (reference)
34 to 54 {3.5 to 5.5} 44 {4.5} - 9/ 14.3
16-18UN
02 19
34 to 63 {3.5 to 6.5} 44 {4.5} 14 - -
22 54 to 93 {5.5 to 9.5} 74 {7.5} - 11/ 17.5
16-16UN
03
24 59 to 98 {6.0 to 10.0} 78 {8.0} 18 - -
04 27 84 to 132 {8.5 to 13.5} 103 {10.5} 22 13/ 20.6
16-16UN
05 32 128 to 186 {13.0 to 19.0} 157 {16.0} 24 1 -14UNS 25.4
06 36 177 to 245 {18.0 to 25.0} 216 {22.0} 30 13/16-12UN 30.2
177 to 245 {18.0 to 25.0} 216 {22.0} 33 - -
(10) 41
240 to 300 {24.5 to 30.5} 270 {27.5} - 17/16-12UN 36.5
(12) 46 197 to 294 {20.0 to 30.0} 245 {25.0} 36 - -
(14) 55 246 to 343 {25.0 to 35.0} 294 {30.0} 42 - -
00-80 PC290LC-11
--- Page 6 ---
10 Structure and Function Layout Drawing of Urea SCR System
5: DEF tank pressure hose (low temperature side) 8: DEF tank coolant inlet hose
6: DEF pump 9: DEF pressure hose (high-temperature side)
7: DEF suction hose 10: DEF tank heating valve
11: KDPF 12: DEF mixing tube
PC290LC-11 10-7
--- Page 7 ---
Component Parts of Urea SCR System 10 Structure and Function
DEF Injector
Structure of DEF Injector
A: Pressurized sending from DEF pump
B: Coolant inlet
C: Coolant outlet
1: DEF injector
2: DEF inlet connector
3: Coolant inlet connector
4: Coolant outlet connector
5: Electric connector
Function of DEF Injector
• It injects DEF which is pressurized by DEF pump into DEF mixing tube.
• The injection amount is controlled by the valve opening or closing time while the pressure is constant.
• It circulates the engine coolant to prevent it from being heated by the heat from the exhaust pipe.
Operation of DEF Injector
Principle of injection of the injector is described. Following fig-
ure shows the state of injection.
1. Engine controller sends the electrical signal to control DEF
injector.
2. Solenoid (4) moves seal ball (2), and seal ball (2) leaves
from injection port (1) to make opening state.
Pressurized DEF by DEF pump is injected.
3. When the electrical signal is not sent, seal ball (2) closes
injection port (1) with spring force (3), so DEF is not injec-
ted.
10-34 PC290LC-11
--- Page 8 ---
10 Structure and Function Component Parts of Engine System
Operation of VGT
REMARK
Six cylinder engine is shown in this item.
1. The exhaust gas enters (C) of turbine housing (4) and flows out through portion (P) and (D). Portion (P) is
surrounded by plate (5) fixed to turbine housing, nozzle ring (7), and vanes (6).
The area of its passage is changed by sliding push rod (8) to the right or left.
2. Hydraulic actuator (3) moves piston in the actuator up and down with the hydraulic pressure controlled by
EPC valve installed to the front cover, and slides push rod (8) to the right and left.
3. The exhaust gas flowing through vanes (6) rotates blower impeller (10) through shaft (9) joined to turbine
impeller (11). As the result, the blower impeller works as a compressor, and the intake air entering through
(A) is compressed and discharge through (B).
4. When the exhaust gas pressure at inlet (C) of turbine housing (4) is low (engine speed is in low range),
push rod (8) slides to the right and narrows portion (P).
5. The exhaust gas acting on turbine impeller (11) increases, the turbocharger speed increases, and more air
(oxygen) is taken in.
VGT speed sensor (2) detects the rotation of the turbocharger.
PC290LC-11 10-61
--- Page 9 ---
KOMTRAX System 10 Structure and Function
KOMTRAX System
System Diagram of KOMTRAX System
KOMTRAX system consists of KOMTRAX terminal, communication antenna, and GPS antenna
Function of KOMTRAX System
• KOMTRAX system transmits various types of information on the machine. KOMTRAX administrator sees
the information in the office and supplies various services to the customers.
• KOMTRAX system can transmits the following information.
• Positional information
• Working information
• Alarm and failure information
• Fuel consumption information
• Maintenance information
• Machine working condition information
REMARK
To provide the services, you need to establish radio station for KOMTRAX separately.
10-88 PC290LC-11
--- Page 10 ---
10 Structure and Function Component Parts of Control System
Engine Controller
Structure of Engine Controller
General View
Input and Output Signals of Engine Controller (Machine with KOMTRAX Termi-
nal)
Delphi96Pin “ECM J1”
Pin No. Signal name Input/output signal
Ground/Shield/
1 Injector #1 (-)
Return
Ground/Shield/
2 Injector #2 (-)
Return
Ground/Shield/
3 Injector #3 (-)
Return
4 (*1) -
5 (*1) -
6 (*1) -
7 (*1) -
8 (*1) -
9 Sensor power supply relay Output
Ground/Shield/
10 IMV (-)
Return
PC290LC-11 10-115
--- Page 11 ---
CLSS 10 Structure and Function
When Control Lever is Stroked to the End and Cylinder is in Stroke End Posi-
tion (When Relief)
2
3
4
1
5 6
7
8 Min.
Max.
9
Max. Min.
10
16 13
11
15 12
14
G0000139
10-142 PC290LC-11
--- Page 12 ---
10 Structure and Function Component Parts of Hydraulic System
Control of Discharged Volume
1. The swash plate angle (a) increases, the difference be-
tween volumes (E) and (F) increases, and also pump dis-
charged volume (Q) increases.
2. Swash plate angle (a) is changed by servo piston (13).
3. Servo piston (13) moves in a linear reciprocating motion
corresponding to the signal pressure from the PC valve
and LS valve.
This linear reciprocating motion is transmitted to rocker
cam (4) through slider (14).
4. Rocker cam (4) supported on the cylindrical surface of cra-
dle (2) slides and pivots on that surface.
5. Output pressure (PEN) of LS valve is supplied to the pres-
sure chamber on large diameter piston side.
6. The pressure receiving areas on the right and left sides of
servo piston (13) are different, and discharged pressure
(self pressure) (PP) of the main pump is constantly sup-
plied to the pressure chamber on the small diameter piston
side.
7. The movement of servo piston (13) is controlled by the dif-
ference between pressure (PP) on the small diameter pis-
ton side and pressure (PEN) on the large diameter piston
side and the ratio of the pressure receiving area between
the small diameter piston and large diameter piston.
Main Pump LS Valve
LS
Abbreviation for Load Sensing
PC290LC-11 10-169
--- Page 13 ---
Component Parts of Hydraulic System 10 Structure and Function
Sectional Views (J-J, L-L, K-K, M-M)
1: Return spring 4: Spring (sequence valve)
2: Merge-divider valve (for LS) 5: Merge-divider valve (main)
3: Valve (sequence valve) 6: Return spring
Boom Valve
7: Boom hydraulic drift prevention valve
10-196 PC290LC-11
--- Page 14 ---
10 Structure and Function Component Parts of Hydraulic System
Operation of LS Select Valve of Control Valve
When Pilot Pressure (BP) is Cut Off
1. Since pilot pressure (BP) is cut off, piston (3) is pressed to
the left by the reaction force of spring (2).
2. When the swing operation is performed, swing LS pres-
sure (P1) passes through swing spool (5) and enters port
(A).
3. Swing LS pressure (P1) pushes valve (1) to the left, and
port (A) is connected to port (B).
4. Swing LS pressure (P1) flows from port (A) through port
(B) to LS shuttle valve (8).
PC290LC-11 10-223
--- Page 15 ---
Layout Drawing of Work Equipment System 10 Structure and Function
Work Equipment System
Layout Drawing of Work Equipment System
Chassis Part
1: Bucket cylinder 6: Fuel supply pump
2: Arm cylinder 7: Engine controller
3: Boom cylinder 8: Attachment circuit accumulator (for high pressure
4: Attachment selector valve circuit)
5: Attachment circuit accumulator (for low pressure cir-
cuit)
10-250 PC290LC-11
--- Page 16 ---
10 Structure and Function Component Parts of Work Equipment System
Operation of EPC Valve of 1st-Line Attachment PPC Valve
When Signal Current is Zero (Coil is De-energized)
Control valve
3
C
T
P
4 2
Self pressure
reducing valve
G0012655
1. When the signal current from the controller does not flow through coil (4), coil (5) is de-energized.
2. Spool (2) is pressed to the right by spring (3).
3. Port (P) is closed and no pressurized oil from the self-pressure reducing valve flows to the control valve.
4. The oil from the control valve is drained into the tank from port (C) through port (T).
PC290LC-11 10-277
--- Page 17 ---
Component Parts of Work Equipment System 10 Structure and Function
Attachment bypass solenoid valve blocks the hydraulic oil
passage between the attachment solenoid valve (P) and
attachment solenoid valve (Q) so as to keep the pressure
on the attachment operation side constant.
P Q
$(3
2. When the attachment control pedal is depressed
Attachment bypass solenoid valve is energized with a cur-
rent supplied from the pump controller (1), it moves the
spool, and the hydraulic oil passage between the attach-
ment solenoid valve (P) and attachment solenoid valve (Q) P Q
is opened.
$(3
Function of Attachment Bypass Solenoid Valve
Attachment bypass solenoid valve is a valve which blocks the hydraulic oil passage between the attachment
solenoid valve (P) and attachment solenoid valve (Q) so that the hydraulic oil from high pressure side to low
pressure side is not leaked. It is enabled when the attachment control pedal is not depressed.
Operation of Attachment Bypass Solenoid Valve
1: Pump controller 2: Attachment bypass solenoid valve
10-304 PC290LC-11
--- Page 18 ---
10 Structure and Function Layout Drawing of Travel System
1: Control valve 4: Fuel supply pump
2: Main pump 5: Engine controller
3: LS-EPC valve 6: Travel alarm
8: Travel control lever 11: Pump controller
9: Machine monitor 12: R.H. travel REVERSE pressure sensor
10: Fuel control dial 13: R.H. travel FORWARD pressure sensor
PC290LC-11 10-331
--- Page 19 ---
Layout Drawing of Undercarriage 10 Structure and Function
Front Idler Detailed Drawing
9: Idler cushion
Specifications of Undercarriage
Quantity of Track Rollers (One Side)
10 pieces
Standard Shoe
Shoe width: 800 mm
Link pitch: 190.3 mm
Number of shoes (each side) 51 pieces
10-358 PC290LC-11
--- Page 20 ---
20 Standard Value Table Standard Value Table for Machine: PC290LC-11
REMARK
• Bring pump discharged pressure P1 and P2 as close as possible to the average pressure when measuring.
• Avoid measuring the near turning point of the graph because the error increases there.
• When measuring with the pump mounted on the machine, if it is impossible to set the engine speed to the
specified speed by using the fuel control dial, take the pump discharged volume and the engine speed at the
time of measurement, and use them as a base for calculating the pump discharged volume at the specified
speed.
PC290LC-11 20-19
--- Page 21 ---
Tools for Testing and Adjusting 30 Testing and Adjusting
Symbol Part No. Part name Q'ty Remarks
Commercially
B Nitrogen gas cylinder 1
available
C 792-610-1400 Regulator 1
D 792-610-1270 Hose 1
E 792-610-1260 Nipple 1
F 792-610-2410 Nipple 1
Replace Tools for Accumulator Bladder on High Pressure Side for Attachment Piping
Symbol Part No. Part name Q'ty Remarks
A 792-610-1703 Charge valve assembly 1 Gas charging tool of accumulator N2
Commercially
B Valve core driver 1 For JIS valve core B type
available
C 09003-03639 Wrench 1 For outside diameter 55 mm
D 790-170-1110 Bladder installation tool 1
Commercially
E Flat-head screwdriver 1
available
Tools to Adjust KomVision Camera Angles
Symbol Part No. Part name Q'ty Remarks
Commercially Niigata Seiki bevel box: BB-180 equiva-
A Digital angle gauge 1
available lent
Tools to Examine KomVision (Camera Calibration)
Symbol Part No. Part name Q'ty Remarks
A - Angle setting calibration marker 1
B - Position setting calibration marker 1
Commercially
C Tripod 1
available
Commercially
D Traffic cone 2 Height : Approx. 70 cm
available
30-12 PC290LC-11
--- Page 22 ---
30 Testing and Adjusting Examine Fuel Pressure
A: Low-pressure circuit measuring position (fuel main C: Return circuit measuring position (supply pump
filter inlet side) drain port)
B: Low-pressure circuit measuring position (fuel main D: Negative pressure circuit measuring position (sup-
filter outlet side) ply pump inlet)
For testing the fuel pressure to perform troubleshooting, refer to this section.
How to Examine Fuel Pressure
Examine Low-Pressure Circuit (Fuel Main Filter Inlet Side)
1. Open the side cover on the right side of the engine and re-
move fuel pressure pickup plug (1) on the inlet side of the
fuel main filter.
PC290LC-11 30-39
--- Page 23 ---
Examine SCR Related Functions 30 Testing and Adjusting
7. Check that “0” of “Test State” is flashing.
REMARK
Flashing of “0” indicates “Waiting for the start (default)”,
and test can be performed. Display other than “0” appears,
follow instructions according to “Parameter list of test
state”.
8. Press F1 to start “DEF Pump Pressure Up Test”.
F1: Starts “DEF Pump Pressure Up Test”.
F2: Stops “DEF Pump Pressure Up Test”. (When “STOP”
is displayed.)
F5: Returns the screen to “SCR Service Test” screen.
NOTICE
“Test State” does not change to “10” and test does not
start even if F1 is pressed, turn starting switch to OFF
position once, and repeat the testing procedure from
step 1.
REMARK
• Display of “Test State” changes to flashing of “10”, and
value of “DEF Pump Pressure” increases. While the
pressure is increasing, display of “Remaining Permitted
Test Time” is counted down from “1800 to 0 sec”, and
when it reaches to “0 sec”, the test will be finished au-
tomatically.
• When the display of “Test State” is “11” to “41”, follow
“Parameter list of Test State”.
• When the value of “DEF Pump Pressure” exceeds
“900 kPa” within 1800 seconds of “Remaining Permit-
ted Test Time”, DEF pump and DEF pressure line are
normal. Press F2 to complete the test.
• If the value of “DEF Pump Pressure” does not increase, check each part of DEF pressure line for leak-
age, or check by sound and vibration that DEF pump operates. However, perform the checking of each
part of DEF pressure line for leakage, and DEF pump for operation, before “Remaining Permitted Test
Time” becomes “0sec”.
• If the value of “DEF Pump Pressure” does not exceeds 800 kPa after approximately 200 seconds are
elapsed, DEF stops operation automatically and failure code [CA1682] is displayed. If the failure code
is displayed, perform troubleshooting.
9. When the display of “Test State” changes from flashing of
“20” to flashing of “0”, press F5.
REMARK
• The display of “20” of “Test State” indicates that DEF
purge is in progress, and it starts automatically and
stops in 5 minutes at maximum.
• The display of “0” of “Test State” indicates “Wait for the
start (default)”, and is ready for test again.
30-66 PC290LC-11
--- Page 24 ---
30 Testing and Adjusting Clean DEF Pump
2) Check the monitoring information of (a) to (d).
Details of the monitoring information are as follows.
1: Thawing is in process.
2: Thermal insulation is in process.
3: OFF
• When one or more of the status of the monitoring
information (a) to (d) is “1”:
DEF is frozen. Thawing is in process. Keep the
engine speed at low idle and wait until all the
states of (a) to (d) of the monitoring information
become “2” or “3”. And then, go to Step 3.
• When the monitoring information of (a) to (d) are
“2” or “3”:
DEF is not frozen. Go to Step 3.
3. Show the Abnormality Record screen. For details, see “How to See Abnormality Record (Mechanical Sys-
tems)” and “How to See Abnormality Record (Electrical Systems)”.
4. Make sure that the failure code (other than [CA1682], [CA3574], and [CA3596]) with the action level is not
shown.
NOTICE
If the failure code (other than [CA1682], [CA3574], and [CA3596]) is shown, see TROUBLESHOOT-
ING to do the troubleshooting.
REMARK
The failure codes [CA1682], [CA3574], and [CA3596] can be shown when foreign materials in the tank are
caught to the DEF pump.
CA1682: DEF Pump Priming Error
CA3574: DEF Pump Pressure Too Low Error
CA3596: DEF Pump Pressure Unstable Error
5. Stop the engine.
k Parts and oil are still very hot immediately after the engine is stopped. It can cause burn injury.
Wait for the temperature to go down, and then start the work.
6. Check the stored condition and procedure to add DEF.
1) Make sure that the pump or container with corrosion resistance is used to add DEF.
2) Before you add DEF, be sure to clean around the filler port.
REMARK
For details, see the Service news “AT16201”.
7. Clean the surface of DEF pump, around the DEF tank filler port, and inside of the DEF tank cap.
REMARK
• Use water and brush to clean the surface of DEF pump, around the DEF tank filler port, and inside of
the DEF tank cap. Fully clean up the dirt.
• If they are not cleaned fully, foreign material can go into them when you replace the DEF filler port filter
or when you clean the DEF pump.
PC290LC-11 30-93
--- Page 25 ---
Examine and Adjust Oil Pressure in Pump LS Control Circuit 30 Testing and Adjusting
1. Open the cover on the right side of the machine, and re-
move oil pressure pickup plugs (PFC), (PRC), (PLSFC),
(PLSRC).
(PFC): Front pump discharge pressure pickup port
(PRC): Rear pump discharge pressure pickup port
(PLSFC): Front load pressure pickup port
(PLSRC): Rear load pressure pickup port
30-120 PC290LC-11
--- Page 26 ---
Examine and Charge Accumulator Nitrogen Gas Pressure for Attach-
30 Testing and Adjusting ment (High Pressure Side)
Examine and Charge Accumulator Nitrogen Gas Pressure for Attachment
(High Pressure Side)
Examine and Charge Tools for Accumulator Nitrogen Gas Pressure for Attachment
Symbol Part No. Part name Q'ty Remarks
A 792-610-1703 Charge valve assembly 1
Commercially
B Nitrogen gas cylinder 1
available
C 792–610–1400 Regulator 1