PDF Service Manual Komatsu SK1026-5N Skid Steer Loader - 3 MB

This service and repair manual provides complete maintenance instructions for the Komatsu SK1026-5N Skid Steer Loader (serial number A80001 and up).

It is filled with detailed procedures for troubleshooting, disassembly, and reassembly of all major components.

Technicians will find the clear diagrams and specifications invaluable for performing accurate and efficient repairs.

This manual is essential for keeping your skid steer productive and reliable.

PDF Viewer
Viewer loads when you scroll here
SHARE THIS MANUAL
Download the PDF Manual
WAWhatsApp fFacebook 𝕏X TGTelegram ✉Email
PDF viewer loading area

Text Preview from This Manual

The text below was extracted from the visible preview pages to help you confirm the manual contents before download.

--- Page 1 ---
CEBM014201

Shop
Manual


                  SK1026-5N
                  SKID STEER LOADER


          SERIAL NUMBERS               SK1026-5N                         A80001                     and UP


This material is proprietary to Komatsu America Corp. and is not to be reproduced, used, or disclosed except in accordance
with written authorization from Komatsu America Corp.

It is our policy to improve our products whenever it is possible and practical to do so. We reserve the right to make changes or
add improvements at any time without incurring any obligation to install such changes on products sold previously.

Due to continuous programs of research and development, periodic revisions may be made to this publication. It is
recommended that customers contact their distributor for information on the latest revision.


July 2009                                                                                  Copyright 2009 Komatsu
Printed in USA                                                                        DataKom Publications Division
                                                                                                            00-11

--- Page 3 ---
FOREWORD                                                                                 HOISTING INSTRUCTIONS
12
HOISTING INSTRUCTIONS                                                                                                           00


Hoisting                                                    00
                                                                      can result. Hooks have maximum strength at the middle
                                                                      portion.
            WARNING! Heavy parts (25 kg or more)
                     must be lifted with a hoist etc.
                     In the DISASSEMBLY AND
                     ASSEMBLY section, every
                     part weighing 25 kg or more is
                     indicated clearly with the sym-
                     bol.


●    If a part cannot be smoothly removed from the machine
     by hoisting, the following checks should be made:           3.   Do not sling a heavy load with one rope alone, but sling
1.   Check for removal of all bolts fastening the part to the         with two or more ropes symmetrically wound on to the
     relative parts.                                                  load.
2.   Check for existence of another part causing interface
     with the part to be removed.                                            WARNING! Slinging with one rope may
                                                                                      cause turning of the load dur-
                                                                                      ing hoisting, untwisting of the
Wire Ropes                                                  00

                                                                                      rope, or slipping of the rope
                                                                                      from its original winding posi-
1.   Use adequate ropes depending on the weight of parts to                           tion on the load, which can
     be hoisted, referring to the table below:                                        result in a dangerous accident
Wire ropes
                                                                 4.   Do not sling a heavy load with ropes forming a wide
(Standard “Z” or “S” twist ropes without galvanizing)                 hanging angle from the hook. When hoisting a load with
          Rope diameter                Allowable load                 two or more ropes, the force subjected to each rope will
                                                                      increase with the hanging angles. The table below
               mm                      kN           tons              shows the variation of allowable load (kg) when hoist-
                                                                      ing is made with two ropes, each of which is allowed to
                10                     9.8          1.0               sling up to 1000 kg vertically, at various hanging angles.
                                                                      When two ropes sling a load vertically, up to 2000 kg of
               11.2                   13.7          1.4               total weight can be suspended. This weight becomes
                                                                      1000 kg when two ropes make a 120° hanging angle. On
               12.5                   15.7          1.6               the other hand, two ropes are subject to an excessive
                14                    21.6          2.2               force as large as 4000 kg if they sling a 2000 kg load at a
                                                                      lifting angle of 150°.
                16                    27.5          2.8
                18                    35.3          3.6
                20                    43.1          4.4
               22.4                   54.9          5.6
                30                    98.1          10.0
                40                    176.5         18.0
                50                    274.6         28.0
                60                    392.2         40.0

★ The allowable load value is estimated to be 1/6 or 1/7 of
   the breaking strength of the rope used.
2. Sling wire ropes from the middle portion of the hook.
   Slinging near the edge of the hook may cause the rope to
   slip off the hook during hoisting, and a serious accident


SK1026-5N                                                                                                               00-71

--- Page 4 ---
FOREWORD                                                                                      CONVERSION TABLES
12
CONVERSION TABLES                                                                                                             00


Method of Using the Conversion Table                                                                                          00


The Conversion Table in this section is provided to enable simple conversion of figures. For details of the method of using the
Conversion Table, see the example given below.

EXAMPLE
● Method of using the Conversion Table to convert from millimeters to inches.
1. Convert 55 mm into inches.
   A. Locate the number 50 in the vertical column at the left side, take this as b, then draw a horizontal line from b.

     B. Locate the number 5 in the row across the top, take this as c, then draw a perpendicular line down from c.

     C. Take the point where the two lines cross as d. This point d gives the value when converting from millimeters to
        inches. Therefore, 55 millimeters = 2.165 inches.

2.   Convert 550 mm into inches.
     A. The number 550 does not appear in the table, so divide by 10 (move the decimal one place to the left) to convert it to
        55 mm.

     B. Carry out the same procedure as above to convert 55 mm to 2.165 inches.

     C. The original value (550 mm) was divided by 10, so multiply 2.165 inches by 10 (move the decimal one place to the
        right) to return to the original value. This gives 550 mm = 21.65 inches.

                                                                                  c
Millimeters to inches                                                                          1 mm = 0.03937 in
                     0          1         2          3          4         5           6        7          8         9
           0         0          0.039     0.079      0.118      0.157     0.197       0.236    0.276      0.315     0.354
           10        0.394      0.433     0.472      0.512      0.551     0.591       0.630    0.669      0.709     0.748
           20        0.787      0.827     0.866      0.906      0.945     0.984       1.024    1.063      1.102     1.142
           30        1.181      1.220     1.260      1.299      1.339     1.378       1.417    1.457      1.496     1.536
           40        1.575      1.614     1.654      1.693      1.732     1.772       1.811    1.850      1.890     1.929
                                                                          d
           50        1.969      2.008     2.047      2.087      2.126     2.165       2.205    2.244      2.283     2.323
b
           60        2.362      2.402     2.441      2.480      2.520     2.559       2.598    2.638      2.677     2.717
           70        2.756      2.795     2.835      2.874      2.913     2.953       2.992    3.032      3.071     3.110
           80        3.150      3.189     3.228      3.268      3.307     3.346       3.386    3.425      3.465     3.504
           90        3.543      3.583     3.622      3.661      3.701     3.740       3.780    3.819      3.858     3.898


SK1026-5N                                                                                                            00-171

--- Page 5 ---
GENERAL                                        TECHNICAL DATA

Machine Overall Dimensions with Pallet Forks


Machine Overall Dimensions with Grapple Fork


SK1026-5N                                               01-51

--- Page 6 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD

12


                          MEMORANDUM


SK1026-5N                              10-31

--- Page 7 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                                                                      FINAL DRIVE

Description
The final drive motor consists of:
1. 2-speed hydraulic motor
2. Selector valve
3. Reduction gearing


Hydraulic Motor
Function
The hydraulic motor is of the axial piston type, and converts hydraulic energy supplied by the pump into rotary motion.


Operation
•   The hydraulic oil arriving from the selector valve is sent on to the
    valve plate (1). When the oil is sent to port “A” of the valve, it
    flows into the corresponding port on the cylinder block (2) and
    presses against the pistons (3).
•   This pressure is converted into rotary motion by a swash plate (4)
    and transmitted to shaft (5). The shaft and cylinder block have been
    integrated into one piece by means of splined teeth.
•   The return oil is sent to the pump through port “B”.
•   Rotation in the opposite direction is achieved by sending the oil to
    port “B” instead of to port “A”.


SK1026-5N                                                                                                          10-131

--- Page 8 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                                          HYDRAULIC PUMP

        iii. Center line X of rocker cam (4) maintains swash plate
             angle α in relation to the axial direction of cylinder block
             (9), and flat surface A moves as a cam in relation to shoe
             (7). In this way, piston (8) slides on the inside of cylinder
             block (9), so a difference between volumes E and F is
             created inside cylinder block (9). Suction and discharge is
             carried out by this difference E-F. In other words, when
             cylinder block (9) rotates and the volume of chamber E
             becomes smaller, the oil is discharged during that stroke.
             On the other hand, the volume of chamber F becomes
             larger, and as the volume becomes bigger, oil is sucked in.
             If the direction of swash plate angle is changed, the
             relation between discharge and suction of port PA, PB
             reverse (Fig. 3).

Control of Fluid Flow

•   If swash plate angle α becomes larger, the difference between
    volumes E and F becomes larger and discharge amount Q
    increases.
•   Swash plate angle α is changed by control piston (5).
•   Control piston (5) moves in a reciprocal movement (↔) according
    to the signal pressure from pilot line (PPC and AS valves). This
    straight line movement is transmitted through slider (6) to rocker
    cam (4), which is supported by the cylindrical surface to cradle,
    slides in a rotating movement in direction ( ).


•   On this pump, maximum swash plate angle is ±15.8o.


•   Screw A restricts to the maximum stroke of control piston (i.e.
    maximum displacement of each pump). When screw A is tightened,
    maximum displacement decreases, and when screw A is loosened,
    maximum displacement increases. This screw should be adjusted
    when the machine does not travel straight or machine maximum
    speed is little bit wrong.
•   Screw B is the fine adjuster of neutral position of control piston (5).
    That adjustment prevents machine from creep.


SK1026-5N                                                                             10-231

--- Page 9 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                              ANTI ENGINE-STALL VALVE (AS VALVE)

Operation


•   The oil from the charge pump (2) flows through a orifice (3) installed in the main piston pump. Oil always flows to pump
    charge circuit.
•   Charge pump (2) is a fixed capacity pump, so that discharge flow is proportionate to engine speed. When oil from the
    charge pump (2) passes through the orifice, differential pressure is generated at port A and port B. This differential
    pressure actuates the differential pressure sensing valve (1G) and produces hydraulic force F.
•   Because of the hydraulic force F, the differential pressure sensing valve (1G) is moved > direction. That causes a change
    in spring (1D) load. In port C, the AS valve output pressure that is balanced with spring (1C) and (1D) load is generated
    by reducing charge pressure from port G. So the AS valve output pressure corresponds with charge flow that changes with
    engine (5) revolution.


SK1026-5N                                                                                                          10-331

--- Page 10 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                    CONTROL VALVES


                                        Torque Values

 a.    11.3 ±1.5 N•m (100 ±13 lbf in)

 b.    31.9 ±2.5 N•m (24 ±2 lbf ft)

  c.   23.5 ±3.9 N•m (17 ±3 lbf ft)


SK1026-5N                                                        10-431

--- Page 11 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                                                             CONTROL VALVES


                                                                      Criteria

                                                   Standard Size                        Repair Limit
 No.           Check Item                                                                                      Remedy
                                      Free    Height      Installed     Installed     Free     Installed
                                      (Outside ∅)          Length         Load       Height      Load

                                      32.9 x 18.2 mm       18 mm         74.0 N                 59.2 N
 1.    Spring of unload valve                                                          -
                                      (1.30 x 0.72 in)    (0.71 in)     (16.6 lbf)             (13.3 lbf)

                                      18.7 x 9.3 mm        16 mm         3.4 N                  2.7 N
 2.    Spring of unload valve                                                          -
                                      (0.74 x 0.37 in)    (0.63 in)     (0.8 lbf)              (0.6 lbf)

       Spring of pressure              15.4 x 6 mm         13 mm         2.5 N                  2.0 N
 3.    compensation valve                                                              -
                                      (0.61 x 0.24 in)    (0.51 in)     (0.6 lbf)              (0.5 lbf)

       Spring of pressure              20 x 8.4 mm         12 mm         6.9 N                  5.5 N           Replace
 4.    compensation valve                                                              -
                                      (0.79 x 0.33 in)    (0.47 in)     (1.6 lbf)              (1.2 lbf)    springs if there
       Spring of combination          37.5 x 16.6 mm      22.5 mm        177.5 N                142.0 N      is damage or
 5.                                                                                    -                      deformation
       circulating valve              (1.48 x 0.65 in)    (0.89 in)     (39.9 lbf)             (31.9 lbf)

       Spring of leveling             37.5 x 15.4 mm      22.5 mm        66.7 N                 53.4 N
 6.                                                                                    -
       circulating valve              (1.48 x 0.61 in)    (0.89 in)     (15.0 lbf)             (12.0 lbf)

       Spring of series - parallel    38.3 x 15.2 mm       24 mm         161.8 N               129.5 N
 7.                                                                                    -
       circuit switching valve        (1.51 x 0.60 in)    (0.95 in)     (36.4 lbf)             (29.1lbf)

                                      30.2 x 9.4 mm        23 mm         2.9 N                  2.4 N
 8.    Spring of flow divider                                                          -
                                      (1.19 x 0.37 in)    (0.91 in)     (0.7 lbf)              (0.5 lbf)

                                                         Torque Value

 a.    53.0 ±5.9 N•m (39 ±4 lbf ft)

 b.    139.7 ±22.1 N•m (103 ±16 lbf ft)

  c.   22.1 ±2.5 N•m (16 ±2 lbf ft)

 d.    8.3 ±1.5 N•m (74 ±13 lbf in)


SK1026-5N                                                                                                          10-531

--- Page 12 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                                             SOLENOID VALVE

12
SOLENOID VALVE

Valve Group ST1
Servo control - Parking Brake - 2nd. Speed


Function

1.   2nd. speed                              A Port - To travel motors (PP1 port)
2.   Servo control                           B Port - To PPC valve
3.   Parking brake                           C Port - To travel motors (PP2 port)
                                             P Port - From hydraulic pump (E1 port)
                                             T Port - To hydraulic tank
                                             S Port - To accumulator


SK1026-5N                                                                                10-631

--- Page 13 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                     R.H. PPC VALVE (STANDARD)


1.   Spool                6.   Nut
2.   Metering spring      7.   Joint
3.   Centering spring     8.   Cover
4.   Piston               9.   Stopper
5.   Disc                 10. Body


SK1026-5N                                                   10-731

--- Page 14 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                                                          L.H. PPC VALVE (STANDARD)

Function

1.   Neutral
     Ports P1 and P2 of the PPC valve are connected to drain chamber D
     through fine control hole f in spool (Fig. 1).

2.   During Fine Control
     (Neutral ➬ Fine Control)
     When piston (4) starts to be pushed by disc (5), retainer (9) is
     pushed; spool (1) is also pushed by metering spring (2), and moves
     down. When this happens, fine control hole f is shut off from drain
     chamber D, and at almost the same time, it is connected to pump
     pressure chamber PP, so pilot pressure oil from the control pump
     passes through fine control hole f and goes to port P1. When the
     pressure at port P1 becomes higher, spool (1) is pushed back and
     fine control hole f is shut off from pump pressure chamber PP.

     At almost the same time, it is connected to drain chamber D to
     release the pressure at port P1. When this happens, spool (1) moves
     up or down so that the force of metering spring (2) is balanced with
     the pressure at port P1. The relationship in the position of spool (1)
     and body (10) (fine control hole f is at a point midway between
     drain hole D and pump pressure chamber PP) does not change even
     if the pressure at port P1 becomes max. Therefore, metering spring
     (2) is compressed proportionally to the amount of movement of the
     control lever, so the pressure at port P1 also rises in proportion to
     the travel of the control lever (Fig. 2).


3.   During Fine Control (When The Lever Is Returned)
     (fine control ➬ neutral)
     When disc (5) starts to be returned, spool (1) is pushed up by the
     force of centering spring (3) and the pressure at port P1. When this
     happens, fine control hole f is connected to drain chamber D and
     the pressure oil at port P1 is released. If the pressure at port P1
     drops too far, spool (1) is pushed down by metering spring (2), and
     fine control hole f is shut off from drain chamber D. At almost the
     same time, it is connected to pump pressure chamber PP, and the
     pump pressure is supplied until the pressure at port P1 recovers to a
     pressure that corresponds to the lever position (Fig. 3).


SK1026-5N                                                                                        10-831

--- Page 15 ---
STRUCTURE, FUNCTION AND
MAINTENANCE STANDARD                   CYLINDERS


                          MEMORANDUM


SK1026-5N                                 10-931

--- Page 16 ---
STANDARD VALUE TABLES                                                                                                   STANDARD SERVICE VALUE TABLE

                                                                             Machine model                                               SK1020-5N and SK1020-5NA

Category                                                  Item                       Measurement Conditions                     Unit    Standard     Service Limit Value
                                                                                                                                          Value
                                          Pilot system travel                                                                            5.5 (80)      4.0-7.0 (58-111)
                                          forward (start-up) *
  Pilot and secondary circuit pressure


                                          Pilot system travel                                                                           14.5 (210)     14-15 (203-218)
                                          (maximum)
                                          Pilot system travel                                                                            5.5 (80)      4.0-7.0 (58-111)
                                          reverse (start-up) *          •   Engine speed: 2500 ± 10 rpm
                                          Pilot system travel           •   Oil temperature: 45-55°C (113-131°F)                 bar
                                          reverse (maxi-                •   Machine raised from the ground                      (psi)   14.5 (210)     14-15 (203-218)
                                          mum)
                                                                        •   * Pressure of wheels at start of rotation
                                          Pilot system travel
                                          to right or left                                                                              14.5 (210)     14-15 (203-218)
                                          (maximum)
                                          Pilot system with
                                          parking brake                                                                                  5.5 (80)       min. 22 (319)
                                          disengaged
                                                                        •   Engine speed: Maximum
                                                                        •   Oil temperature: 45-55°C (113-131°F)
  Engine speed (with load)


                                          With travel pump              •   2nd. speed                                                    2600           2500-2700
                                                                        •   Travel lever: At full stroke
                                                                        •   Parking brake: Applied
                                                                        •   Engine speed: Maximum                               rpm
                                                                        •   Oil temperature: 45-55°C (113-131°F)
                                          With travel and               •   2nd. speed
                                          equipment pump                                                                                  2525           2400-2650
                                                                        •   Travel lever: At full stroke
                                                                        •   Parking brake: Applied
                                                                        •   Raise: At end of stroke
                                                         Total work
                                                         equipment
                                                         (Downward
                                                         movement
                                                         of bucket                                                                      Max. 130          Max. 200
                                                         teeth)                                                                          (5.12)            (7.87)
  Hydraulic drift of the work equipment


                                                         Rasing
                                                         cylinder
                                                         (Retraction)                                                                    Max 15           Max. 25
                                          Front bucket


                                                                                                                                          (0.59)            (0.98)
                                                                                                                                mm
                                                                                                                                (in)

                                                                        •   In this position, measure extension or retraction
                                                         Bucket             of each cylinder, and any leakages occurring
                                                         cylinder           when a load is applied to the tips of the bucket
                                                         (extension)        teeth.
                                                                        •   Horizontal and level ground                                  Max. 8           Max. 15
                                                                        •   Engine: Switched off
                                                                                                                                          (0.32)            (0.59)
                                                                        •   Oil temperature: 45-55°C (113-131°F)
                                                                        •   Take measurements as soon as the engine
                                                                            stops
                                                                        •   Measure the variations every 5 minutes and
                                                                            check the total variation after 15 mins.


SK1026-5N                                                                                                                                                            20-5

--- Page 17 ---
TESTING AND ADJUSTING                                                    ENGINE COMPONENTS
  B. Loosen the lock nut (3) and unscrew the adjustment screw (4)
     by approximately 1 turn.


  C. Insert feeler gauge B1 between rocker (6) and valve cap (5).
     Rotate adjusting screw (4) until it rubs against feeler gauge B1.
     Secure this position with nut (3).
     ★ After locking nut (3), check the valve clearance again.
  D. Adjust clearance between valve and rockers to the following
     values:

                    Suction valves             Exhaust valves
With engine cold    0.20 mm (0.008 in)        0.20 mm (0.008 in)

  E. After adjusting the No. 1 cylinder, rotate drive shaft 180° each
     time and adjust the valve clearance of the other cylinders
     according to the ignition sequence.
     ★ Ignition sequence: 1 - 3 - 4 - 2.


SK1026-5N                                                                             30-7

--- Page 18 ---
TESTING AND ADJUSTING                                                ADJUSTING SERVO-CONTROL SAFETY

ADJUSTING SERVO-CONTROL SAFETY SENSOR
            WARNING! Before proceeding with any adjustments, be sure all work equipment is on the ground and
                     there controls neutralized. Be sure the parking brake is set and the machine is on a flat
                     level surface. Stop the engine and remove the ignition key.


1.   Lower the LH safety bar (1) and adjust the position of sensor (2) by
     loosening then tightening adjustment nuts (3).


     ★ Distance between safety bar and sensor: 1 mm (0.039 in)


SK1026-5N                                                                                               30-17

--- Page 19 ---
TESTING AND ADJUSTING                                                       CONTROL VALVE
Valve Adjustment
★ The unloading valve cannot be re-adjusted, only replaced.
Adjustment Of Main Relief Valve
1. If the pressures measured for the working equipment and machine
    travel do not fall within normal values, adjust the main relief valve
    (1) as follows:
    ★ Loosen lock nut (2) and rotate the adjusting screw (3).
         • To INCREASE pressure, turn in a CLOCKWISE
              direction.
         • To DECREASE pressure, turn in a
              COUNTERCLOCKWISE direction.
    ★ Each turn of the adjusting screw (3) varies the pressure by
         about 56.1 kg/cm2 (798 psi).
2. Lock the nut (2).

            Nut: 69 ± 10 N·m (51 ± 7 lbf ft)

    ★ After adjustment, check the adjustment of the main relief valve
      with the same procedures as used for the measurements.


SK1026-5N                                                                            30-27

--- Page 21 ---
TROUBLESHOOTING                                                     POINTS TO REMEMBER WHEN TROUBLE-
3.   Check before troubleshooting.

     A. Check the oil level.

     B. Check for any external leakage of oil from the piping or hydraulic equipment.

     C. Check the travel of the control levers.

     D. Check the stroke of the control valve spool.

     E. Other maintenance items can be checked externally, so check any item that is considered to be necessary.

4.   Confirming the failure.

     A. Confirm the extent of the failure yourself, and judge whether to handle it as a real failure or as a problem with the
        method of operation, etc.
        ★ When operating the machine to reenact the troubleshooting symptoms, do not perform any investigation or
            measurement that may make the problem worse.

5.   Troubleshooting.

     A. Use the results of the investigation and inspection in Steps 2 - 4 to narrow down the causes of the failure, then use the
        troubleshooting flowchart to locate the position of the failure exactly.

     B. The basic procedure for troubleshooting is as follows.

         i.    Start from the simple points.

         ii.   Start from the most likely points.

         iii. Investigate other related parts or information.

6.   Measures to remove root cause of failure.

     A. Even if the failure is repaired, if the root cause of the failure is not repaired, the same failure will occur again.

     B. To prevent this, always investigate why the problem occurred. Then, remove the root cause.


SK1026-5N                                                                                                                       40-5

--- Page 22 ---
TROUBLESHOOTING                                                     PRECAUTIONS WHEN PERFORMING MAIN-

Points to Remember When Handling Hydraulic Equipment
With the increase in pressure and precision of hydraulic equipment, the most common cause of failure is dirt (foreign material)
in the hydraulic circuit. When adding hydraulic oil, or when disassembling or assembling hydraulic equipment, it is necessary
to be particularly careful.

1.   Be careful of the operating environment.
     Avoid adding hydraulic oil, replacing filters, or repairing the machine in rain or high winds, or places where there is a lot
     of dust.

2.   Disassembly and maintenance work in the field.
     If disassembly or maintenance work is carried out on hydraulic
     equipment in the field, there is danger of dust entering the
     equipment. It is also difficult to confirm the performance after
     repairs, so it is desirable to use unit exchange. Disassembly and
     maintenance of hydraulic equipment should be carried out in a
     specially prepared dust proof workshop, and the performance
     should be confirmed with special test equipment.


3.   Seal or cover all openings of disconnected piping.
     After any piping or equipment is removed, the openings should be
     sealed with caps, tape, or vinyl bags to prevent any dirt or dust from
     entering. Never leave any openings opened or blocked with a rag,
     this could cause particles or dirt to get into the system. Drain all oil
     into a container and not unto the ground and be sure to follow the
     proper environmental regulation for any disposal of oil.


4.   Do not let any dirt, or dust get in during refilling operations.
     Be careful not to let any dirt or dust get in when refilling with
     hydraulic oil. Always keep the oil filler and the area around it clean,
     and also use clean pumps and oil containers. If an oil cleaning

View the complete manual on HeyDownloads →