--- Page 1 ---
BI643728
                                                                     Revision No 1
                                                                       3 July 2014


Operation
Manual
CL210 Load Haul Dump
Bucyrus Serial Number 5004091 (Caterpillar Serial Number BA200542)


                                     SAFETY.CAT.COM

--- Page 3 ---
BI643728

                                                                            Operation Manual


                                          Section   2
                        General Safety and Precautions
This section contains specific safety precautions that shall be followed whilst the machine is
being used by suitably qualified operators. This list is NOT all inclusive and a measure of
commonsense should always be applied together with established and ongoing site specific
risk assessment and safety procedures.

 ONLY TRAINED AND AUTHORISED OPERATORS SHALL OPERATE THIS MACHINE

DO NOT           use the machine for any purpose other than its intended use.

DO NOT           for any reason exceed the indicated capacity of the machine.

DO NOT           operate the machine unless all operator checks and scheduled servicing
                 have been performed. Report any damage or faulty operation immediately
                 and do not operate the machine until the fault has been corrected.

DO NOT           tie down or tow equipment such that the chains or slings are not rated for
                 the capacity of the machine and equipment.

DO NOT           operate the machine unless:

                     There are no tags attached stating otherwise.
                     All covers and guards are correctly installed.
                     Personal protective equipment is worn.

DO NOT           start the machine unless:

                     There are no tags attached stating otherwise.
                     The area around the machine is clear.
                     The park brake is applied.
                     Transmission is in neutral.
                     All water and oil levels are checked.
                     All site specific checks are completed.

DO NOT           leave the machine unless:

                     The machine is parked in a safe place.
                     The transmission is in neutral.
                     The park brake is applied and brake head pressure is zero.
                     The lift arms are lowered or any attachment is flat on the ground or
                       supported.
                     The engine is stopped.

DO NOT           work on the machine in low ventilated areas while the engine is running.

ALWAYS           sound the horn before starting the engine to alert anyone who may be
                 around the machine.

ALWAYS           ensure that the operator’s compartment door is closed and made secure
                 before operating the machine.


Rev. 0                       CL210 Load Haul Dump Serial No. 5004091                          5

--- Page 4 ---
BI643728

                                                                                   Operation Manual


TRANSMISSION GEAR CONTROL LEVER

The transmission gear control lever has four positions, first, second, third and fourth.
Shifting from one range to another can be made at any time conditions permitting.
Momentarily decrease engine revs when selecting a higher gear. Momentarily increase
engine revs when selecting a lower gear.


                        The transmission in the machine is modulated. This prevents severe
                        shocks being transmitted through the drive train when the
                        transmission direction is changed.


TRANSMISSION DIRECTIONAL CONTROL LEVER

A directional control lever controls the transmission and direction of travel. This lever has
three positions, forward, neutral and reverse. The engine should be at low idle when the
transmission is shifted from the neutral position to either forward or reverse direction.


                       The transmission must be placed in the neutral position for the starter
                       motor to engage when starting the engine.


                        If the engine starts when the transmission is not in neutral, the
                        machine should be tagged out of service until the problem is rectified.


                                                                              Transmission Gear
                                                                              Control Lever


         Transmission Directional
                   Control Lever


                                                  TRANSMISSION CONTROLS


Rev. 0                              CL210 Load Haul Dump Serial No. 5004091                           15

--- Page 5 ---
BI643728

                                                                          Operation Manual


HORN BUTTON

Pushing this button sounds the air horn.


               It is good operating procedure to sound the horn 2-3 seconds before
               an engine start or whenever approaching blind intersection.


                  Horn Button


                                    RIGHT HAND SIDE OPERATOR’S PANEL


ENGINE SERVICE HOUR METER

This electric meter is mounted on the off driver’s side at the rear of the machine. Use the
hour meter to determine servicing intervals.


                         ENGINE HOUR METER


Rev. 0                          CL210 Load Haul Dump Serial No. 5004091                    25

--- Page 6 ---
BI643728

                                                                            Operation Manual


ELECTRICAL ISOLATION

1.       Ensure the area is clear of any obstructions and area is fit for carrying out safe
         operation and maintenance.
2.       Lower the lift arms or any attachment, shutdown the engine, connect the articulation
         lock and chock the wheels.
3.       All electrical energy is isolated once the engine has stopped.

                  The electrical system installed on this machine is approved/certified
                  as explosion protected for use in underground coal mines and may
                  cause an atmospheric explosion if not maintained and used in its
                  approved state. Such equipment is to be inspected and maintained in
                  accordance with the relevant regulatory authorities rules and
                  regulations and the conditions for which the apparatus has been
                  approved.

                  If any fault or damage is detected to the electrical system it should be
                  reported to the service personnel.

                  Do not bypass shutdown conditions or devices.


                  Isolating the main air isolation valve or completely draining the
                  pneumatic system of air will render the machine unable to be started
                  until it is re-energised.


Rev. 1                         CL210 Load Haul Dump Serial No. 5004091                        35

--- Page 8 ---
BI643728

                                                                                Operation Manual


                  Always use the specified lubricant for the application and the region’s
                  seasonal temperatures. (See Section 23).

                             Filler Cap


                                                        Sight Gauge


                COOLANT EXPANSION TANK


                                                                           FUEL WATER TRAP


Check the air cleaner (see Section 4):

1.       Filter condition indicator.
2.       Replace filter element if indicator is in the red area.
3.       Check intake pipes and hoses for loose or damaged connections.
4.       Check joints are secured.


                  Do not operate the machine with loose intake pipe connection, this
                  will allow particles of dust into engine and cause serious damage.


Rev. 1                           CL210 Load Haul Dump Serial No. 5004091                          45

--- Page 9 ---
BI643728


                                                                           Operation Manual


Check the diesel control system operation:

1.       Run the engine at high idle.
2.       Press the shutdown test button and hold for ten seconds.
3.       Machine should shutdown and the low oil pressure display should be on.
4.       The engine should not restart until the on/off toggle switch is reset.


                     If the engine does not shutdown do not use the machine. Report it to
                     the service personnel for repairs.


Perform low exhaust water shutdown test:

1.       Start diesel engine system and ensure all shutdown systems are operational, allow
         engine to warm up and run for several minutes.


2.       Shut make up tank ball valve and remove blanking plug from the low water shutdown
         test point and open ball valve.
                                                 Main Isolation Valve


     Low Water Shut Down
                Test Point


Rev. 0                           CL210 Load Haul Dump Serial No. 5004091                     55

--- Page 10 ---
BI643728

                                                                         Operation Manual


                                          Section   13
                                  Parking on a Ramp


                 Do not park on a ramp unless absolutely necessary.


1.       Use the concept of engine braking to help slow down the machine by letting up on
         the accelerator pedal.
2.       Apply the brakes and bring the machine to a halt at the side of the road.
3.       Turn the machine toward the rib.
4.       If possible remove the load from the attachment.
5.       Apply the park brake. Observe that the brake head pressure gauge and primary park
         brake valve gauge are on zero.
6.       Always chock the wheels.
7.       Inform mine management of the position of machine.


                 When on steep grades (more than 1:4). Do not rely on the park brake
                 to hold the machine.


                 Always park with attachment into the rib and chock the wheels when
                 on grades of more than 1:4.


Rev. 0                        CL210 Load Haul Dump Serial No. 5004091                  65

--- Page 11 ---
BI643728

                                                                                    Operation Manual


                                           Section   18
                             Air Venting the Fuel System
If the engine misfires or fails to start due to air in the fuel line, the system must be bled as
follows:

1.       Ensure the governor control lever is in the shut off position.
2.       Unscrew the knob on the priming pump sufficiently to release it, then pump in and out
         until positive pressure is observed.
3.       Tighten and secure the priming pump.
4.       Start the engine. If it misfires or smokes with the engine running repeat the above.


                  Check the fuel tank contents gauge before venting the system.


                  Check the fuel water separation bowl before venting the system.


                                                                          Manual Fuel Primer


                                              FUEL PRIMING PUMP


Rev. 0                          CL210 Load Haul Dump Serial No. 5004091                                   75

--- Page 12 ---
BI643728

                                                                Operation Manual


         If methane concentration is over 1.25%, it should be reported
         immediately!


         Bypassing of the electrical safety system is not allowed under any
         circumstance!


         If the air pressure is below 240 kPa (35 psi), the power up pressure
         switch will not close, and the DCS will not activate


         The start sequence is the same if the methane monitor is not fitted.


Rev. 1               CL210 Load Haul Dump Serial No. 5004091                      85

--- Page 13 ---
BI643728


                                                                                    Operation Manual


                                                                       Side Shift


                                              Fork Tine Pin Block


                                 Fork Tine Heel


 Hydraulic Supply from RAS           Side Shift Cylinders                    Hydraulic Supply from RAS
    Lock Cylinder Lines                                                         Lock Cylinder Lines


                               10000 KG SIDE SHIFT FORK ATTACHMENT


Rev. 1                       CL210 Load Haul Dump Serial No. 5004091                                 95

View the complete manual on HeyDownloads →