PDF Operation and Maintenance Manual CAT 25M3 (CM240) Continuous Miner - 2 MB

This manual provides essential information for the safe operation and routine maintenance of the CAT 25M3 (CM240) Continuous Miner.

It details daily checks, lubrication schedules, and operational best practices.

Adhering to the guidelines in this document is critical for maximizing uptime and ensuring the safety of personnel in underground mining operations.

This is a must-have for all operators and maintenance crews.

PDF Viewer
Viewer loads when you scroll here
SHARE THIS MANUAL
Download the PDF Manual
WAWhatsApp fFacebook 𝕏X TGTelegram ✉Email
PDF viewer loading area

Text Preview from This Manual

The text below was extracted from the visible preview pages to help you confirm the manual contents before download.

--- Page 1 ---
BI016888-03-EN
                                                        A6474X356
                                                        December 2014


Operation and
Maintenance
Manual
CM240 Continuous Miner
Serial Number: GEW00763, GEW00772, GEW00798, GEW00802


                              SAFETY.CAT.COM

--- Page 3 ---
BI016888-03-EN

____________________________________________ Before starting to work

                        Characters and symbols used
                        The following characters and symbols are used for safety instructions
                        and important information in the operating manual.

                        Try to memorize the symbols and their meanings.

                        DANGER!
                        Points in the text marked with this symbol draw your attention to
                        immediately impending danger. Possible consequences are:
                        very serious injury or even death.

                        WARNING!
                        These points contain information on dangerous situations. Possi-
                        ble consequences are: very serious injury or even death.

                        CAUTION!
                        This symbol draws attention to dangerous situations. Possible
                        consequences are: light to moderately serious injuries and ma-
                        chine damage.

                        NOTICE!
                        Points in the text marked with this symbol draw attention to harm-
                        ful situations. Possible consequences are: damage to the ma-
                        chine or damage in the immediate vicinity.

                        IMPORTANT!
                        Points in the text marked with this symbol contain useful tips and
                        information intended to facilitate work for you. They do not warn
                        about harmful or dangerous situations.

                        ■   Items in lists are marked with bullets.

                            –   Points in sub-lists are marked with a long dash at the start of
                                the line.

                         Points in text marked in this way describe individual operations.
                          Follow these instructions step by step. They will help you carry out
                          your work faster and more importantly, safer.


______________________________________________________________
A6474X356                  REV 03                           1.5

--- Page 4 ---
BI016888-03-EN

______________________________________________ Safety instructions

                                Installation and start-up
                inclined face   On inclined faces secure all component parts by chains, e.g. to the
                                support.

  environmental acceptability   When working with oils, greases and other chemical substances, ob-
                                serve the safety regulations applicable to the product. Safety regula-
                                tions can be found on the container or on the Material Safety Data
                                Sheet (MSDS) for the product.

                                Dispose of cleaning rags, etc. which have been soiled with oil, grease
                                or other chemical substances in an environmentally safe manner.

                     controls   When starting up machine, do not operate any controls located inside
                                the operator’s compartment (optional) from outside the compartment.

          starting procedures   Follow the starting procedure instructions in the operations manual.

                    red zone    Do not operate any levers, pedals or controls if anyone is in the red
                                zone. (See Red Zone in Chapter 5 of this manual)

                                Operation
                     training   Operate the machine only if you have a profound knowledge of the
                                control elements and their functions. It is necessary that you have
                                been task trained on the respective Continuous Miner.

              before start-up   Before start-up, ensure that there are no persons or obstructions in
                                your line of travel or in the articulation area when steering the unit.

           protective devices   Check that all protective devices are installed on the machine and func-
                                tion properly.

     operator’s compartment     Clean the operator’s compartment at regular intervals. Ensure that the
                   (optional)   operating symbols are legible in order to avoid any operator errors and
                                resulting accidents.

                                Never climb onto, or climb out of the machine while it is in motion.

                                Do not operate the machine with any part of your body outside of the
                                operator’s compartment in order to prevent body parts from being
                                crushed between the machine and outside objects .

                    traveling   Use extreme caution when traveling in close quarters or in congested
                                or blind-travel areas.

                 passengers     Never carry passengers. Passengers may be thrown off the machine
                                or crushed between the machine and outside objects.

                 safety rules   Always follow all safety rules of each particular mine when operating
                                the machine.

   problems and malfunctions    If problems or malfunctions are encountered while operating the unit, it
                                must be properly shutdown and the problem corrected immediately.
______________________________________________________________
A6474X356                  REV 03                           2.9

--- Page 5 ---
BI016888-03-EN

____________________________________ Overview of safety instructions

                        WARNING!
                        Warn “ALL CLEAR” before starting the conveyor. Failure to do so
                        may result in serious injury or death.

                        IMPORTANT!
                        The “CONV ON” key must be released before “SHIFT”. If “SHIFT”
                        is released first, the conveyor motors will shut off.

                        IMPORTANT!
                        The “FAN ON” key must be released before “SHIFT”. If “SHIFT” is
                        released first, the fan motor will shut off.

                        CAUTION!
                        Always ensure operator safety while operating the machine.

                        CAUTION!
                        Always be alert to hazardous conditions and take corrective ac-
                        tion as necessary.

                        IMPORTANT!
                        Care should be taken not to stall cutters or conveyor during cut-
                        ting operations. Severe damage to motors and gear boxes could
                        occur if cutters or conveyor are repeatedly stalled.

                        IMPORTANT!
                        Tram is limited in the forward direction while the cutters are run-
                        ning with the cutter head feedback circuit. As the cutters begin to
                        cut the material from the face the sump speed will automatically
                        slow the tram to prevent over sumping the machine.

                        IMPORTANT!
                        Inspection of the bits and bit blocks before the start of each shift
                        will reduce later problems. Mining with dull, bent or broken bits
                        and bit blocks increases dust and noise levels, as well as putting
                        excessive strain on both cutter motors and tram components.

                        WARNING!
                        Failure to maintain the hydraulic system will result in damage to
                        its hydraulic components which will result in increased wear and
                        premature failure.

                        IMPORTANT!
                        Schematics may vary from one unit to the next. Consult the parts
                        book for the schematic for your machine.

                        IMPORTANT!
                        During disassembly of control valves, give particular attention to
                        identification of parts for reassembly. Spools are selectively fitted
                        to valve bodies and must be returned to the same bodies from
                        which they were removed. Spools are NOT interchangeable be-
                        tween valve bodies.


 ______________________________________________________________
A6474X356                  REV 03                           2.19

--- Page 6 ---
BI016888-03-EN

____________________________________ Overview of safety instructions

                        WARNING!
                        Each stabilizer cylinder is extremely heavy. The next steps will
                        remove the cylinder from its tractor frame mounting. Be prepared
                        to support the weight from its tractor frame mounting. Be pre-
                        pared to support the weight of the cylinder when it becomes free
                        from the mounting.

                        IMPORTANT!
                        To obtain maximum performance, the duocone seals must be in-
                        stalled accurately to insure uniform loading at the mating faces
                        and achieve a stable running position. Misalignment or cocking of
                        seal rings during assembly can produce non-uniform loading and
                        wobbling of the seals in their housings resulting in leakage due to
                        scoring and/or pumping of debris past the toric rings. Improper
                        installation can also result in breakage of the metal seal rings.

                        NOTICE!
                        Improper care and installation of duocone seals can result in im-
                        mediate leakage or reduced service life.

                        IMPORTANT!
                        The toric must lie uniformly in the seal with the sealing ring and
                        parallel to the seat face. Be sure that the toric is not twisted and
                        that it rests uniformly against the retaining lip or not deeper in one
                        side of the seat than the other.

                        IMPORTANT!
                        Do not get any oil onto the rubber torics!


                        IMPORTANT!
                        Even a small piece of lint can hold the faces apart and cause leak-
                        age!

                        IMPORTANT!
                        A mixture of marking compound and spindle oil is good lube for
                        the gears under light loads for 2-3 revolutions only. Check tooth
                        patterns all round to make sure the pattern/markings are uniform.

                        CAUTION!
                        Be careful not to set fire to any grease or lubricant when heating
                        bearings!

                        IMPORTANT!
                        Observe all applicable fire and safety regulations when heating
                        bearings!


 ______________________________________________________________
A6474X356                  REV 03                           2.29

--- Page 7 ---
BI016888-03-EN

____________________________________________ Storage and transport

Fig. 5 (continued): Lifting points


                                              Lifting eye (30 ton)


                                                  Lifting eye (30 ton)


                                     Bumper


  ______________________________________________________________
  A6474X356                   REV 03                          3.7

--- Page 8 ---
BI016888-03-EN

_____________________________________________________ Installation

Fig. 6 (continued): Safety features on the Continuous Miner


                                                                          Cutter boom safe-
                                                                          ty support (2)


                                                        Conveyor safety
                                                        support (2)


 ______________________________________________________________
 A6474X356                  REV 03                           4.9

--- Page 9 ---
BI016888-03-EN

______________________________________________________ Operation

                          Electrical metering package (optional)

                          The optional electrical metering package (Fig. 12) consists of a group of
                          meters that monitor current draw on the motors, machine voltage, and
                          cutter and conveyor hours of operation.

    “LEFT CUTTER MOTOR”   The “LEFT CUTTER MOTOR” and “RIGHT CUTTER MOTOR” amme-
                    and   ters monitor the current draw by the cutter motors. During normal oper-
   “RIGHT CUTTER MOTOR”   ation, the two meters should indicate approximately the same current
                          draw. If one meter consistently reads higher than the other meter, shut-
                          down the machine (see Shutdown procedure in this chapter) and con-
                          tact Maintenance.

  “LEFT CONVEYOR MOTOR”   The “LEFT CONVEYOR MOTOR” and “RIGHT CONVEYOR MOTOR”
                    and   ammeters monitor the current draw by the conveyor motors. During
 “RIGHT CONVEYOR MOTOR”   normal operation, the two meters should indicate approximately the
                          same current draw. If one meter consistently reads higher than the oth-
                          er meter, shutdown the machine (see Shutdown procedure in this chap-
                          ter) and contact Maintenance.

      “MACHINE VOLTAGE”   The “MACHINE VOLTAGE” voltmeter indicates the control circuit volt-
                          age. During normal operation, the indicator should stay between 855
                          and 1,045 volts (950V ± 10%). Should the meter indicate high or low
                          voltage, shutdown the machine (see Shutdown procedure in this chap-
                          ter) and contact Maintenance.

         “CUTTER HOURS”   The “CUTTER HOURS” meter indicates the hours of running time for
                          the cutter head motors.

      “CONVEYOR HOURS”    The “CONVEYOR HOURS” meter indicates the hours of running time
                          for the conveyor motors.

                          Fig. 12: Electrical metering package (optional)

                              “LEFT CUTTER          “LEFT CONVEYOR       “MACHINE VOLTAGE”
                              MOTOR” ammeter        MOTOR” ammeter       volt meter


                             “RIGHT CUTTER     “RIGHT CONVEYOR       “CUTTER           “CONVEYOR
                             MOTOR” ammeter    MOTOR” ammeter        HOURS” meter      HOURS” meter

______________________________________________________________
A6474X356                REV 03                             5.9

--- Page 10 ---
BI016888-03-EN

______________________________________________________ Operation

           radio remote   The radio remote (Fig. 22) is a battery powered remote used to control
                          the continuous miner during normal operations.

                          WARNING!
                          Radio remote control systems are dangerous. The continuous
                          miner operator cannot operate a remote system until he is proper-
                          ly trained in the operation of the system. Remote control systems
                          sometimes have automatic features of which untrained operators
                          and workers may not be aware.

                          Fig. 22: Radio remote (typical)


                          The radio remote shown may vary from the remote that shipped with
                          your machine.


 ______________________________________________________________
A6474X356                REV 03                             5.19

--- Page 11 ---
BI016888-03-EN

______________________________________________________ Operation

                                         Pillaring red zones (Fig. 33) Remote control offers a significant safety
                                         advantage in partial or complete removal of the pillars in retreat mining
                                         because it places the operator further away from potential collapsing
                                         roof.

                                         Much of the area around the miner must be considered a red zone,
                                         mostly because of extensive unsupported roof and the need for tempo-
                                         rary supports under weakened roof. With remote control, the operator
                                         can position himself safely away from the miner while still retaining a
                                         good view of the mining cycle.

                                         A red zone around the miner is no longer applicable when working in
                                         the opposite right hand pillar, as the operator is now excluded from the
                                         entire working area because of failing roof considerations, even with the
                                         existence of temporary roof supports

                                         When making an additional end cut into the pillar, creating a fender of
                                         coal between the two cuts, additional temporary roof supports are in-
                                         stalled.

                                         Because of roof pressures, the fender will tend to slough its ribs in the
                                         process of eventually crushing. Hence, the operator must stay away
                                         from this fender as well as avoiding the entry and crosscut areas as
                                         shown.

Fig. 33: Pillaring red zones


 Pillaring in a left hand cut red zone     Pillaring in a end cut red zone               Pillaring in a right
                                                                                         hand cut red zone


 ______________________________________________________________
A6474X356                REV 03                             5.29

--- Page 12 ---
BI016888-03-EN

______________________________________________________ Operation

                      Fire suppression in radio remote
                      The control system uses a solenoid output to drive the fire suppression
                      system on the continuous miner. The fire suppression can be activated
                      at any time from the remote control console. If the machine is fitted
                      with the battery backup version of the power supply, the fire suppres-
                      sion can also be activated in battery standby mode. The system will
                      remain in battery standby mode for at least ten minutes after loss of
                      main power to the machine.

                      When in radio mode, the fire suppression can be activated from the ra-
                      dio as follows:

                       Press the “SHIFT” and “FIRE” keys at the same time and hold for
                        two (2) full seconds.

                       After two seconds, the fire suppression system will activate. At this
                        time, the “SHIFT” and “FIRE” keys can be released.


 ______________________________________________________________
A6474X356                REV 03                             5.39

--- Page 13 ---
BI016888-03-EN

______________________________________________________ Operation

                                     The first view in Fig. 37 shows the miner having sumped in at the top of
                                     the coal face. If the operator intends to shear down and up, the depth
                                     of sump should be no more than half a drum diameter; otherwise, a
                                     cusp will be left at the bottom or top after shearing which will require
                                     trimming.

                                     The second view shows the miner in the middle of the downcut.

                                     Having completed the downcut, the third view shows the miner sumped
                                     in about half a drum diameter at the mine bottom.

                                     Finally, the last view shows the miner in the middle of the upcut. The
                                     technique of successively shearing up and down is particularly produc-
                                     tive when the miner is working in conjunction with a continuous haulage
                                     system.
Fig. 37: Shearing up and down


                                          Miner shearing down


        Miner sumping in at mine bottom                                Miner shearing up


 ______________________________________________________________
A6474X356                REV 03                             5.49

--- Page 14 ---
BI016888-03-EN

______________________________________________________ Hydraulic

                      Hydraulic system schematics

                      Abbreviations and Symbols

                      Troubleshooting is easier when you can readily read and understand
                      the diagrams and blueprints of a hydraulic network. To do this, you
                      need to know hydraulic symbols.

                      Graphic symbols denote the type of function a component performs
                      but do not necessarily sh ow i ts s hap e or c ons tr uction . T hes e
                      schematic symbols are used to trace the system flow from the reser-
                      voir to the actual work being performed and then back to the reservoir.
                      The symbols used are shown individually with a functional description
                      where needed. The study of these symbols helps in understanding
                      the system and thereby aids in troubleshooting the system.

                      In a hydraulic schematic, components are represented on a schematic
                      diagram by symbols. Using the hydraulic symbols to trace a circuit will
                      help to define the relationships of the components and circuits. The
                      component symbols are linked together by lines, which represent the
                      hydraulic hoses and pipes on the miner.

                      A schematic diagram is an illustration which shows the hydraulic rela-
                      tionship of the various components in the circuits. A schematic diagram
                      does not show the physical location of the components.

                      IMPORTANT!
                      Schematics may vary from one unit to the next. Consult the parts
                      manual for the correct schematic for your machine.


   ______________________________________________________________
 A6474X356                 REV 03                             5.59

--- Page 15 ---
BI016888-03-EN

______________________________________________________ Hydraulic

Fig. 53: Valve hydraulic symbols


                                                   Check valve


                                Ball valve
                                                                   Conveyor chain take
                                                                       -up valve
                                                                                                  Directional control
                                                                                                         valve

Anti-chatter/maintenance
          valve


  Flow control
     valve          Flow control valve with
                        internal check


                                                         Gathering head float valve                   Pressure reducing
                                                                                                            valve


   Out             In

                                                                 Shuttle
                                                                  valve
   Pressure regulator
         valve

                                    Relief valve
                                                                                         Solenoid valve
                                                                                             2-unit


                                  Water valve,
  Water valve, detent
  hydraulic operated

    ______________________________________________________________
  A6474X356                 REV 03                             5.69

--- Page 16 ---
BI016888-03-EN

______________________________________________________ Hydraulic

                      Conveyor swing circuit
                      Oil is supplied by hydraulic pump section A1 through a 10-micron by-
                      passing pressure filter (tri-filter) to the conveyor swing working section
                      on the main control valve. By manual or remote solenoid control, the
                      spool allows oil to enter the swing circuit. The swing cylinder is a double
                      -acting cylinder. The range on the cylinder will allow the conveyor tail to
                      move 45 degrees off the centerline of machine in both directions. There
                      are two (2) port reliefs in the working section on the main control valve
                      both of which are set at 1,800 psi. The purpose of the port reliefs is to
                      protect the swing cylinder from damage in either right or left direction in
                      the event of an excessive external load due to the impact of the convey-
                      or tail with the rib, haulage vehicle, or some other object.

                      Push the handle and the left hand cylinder will retract, moving the con-
                      veyor tail to left. Pull the handle out and the cylinder will extend, mov-
                      ing the discharge conveyor to the right. The left and right movement is
                      based off standing at the rear of machine looking forward to the cutter
                      head.

                      An optional right hand cylinder may be required for attaching haulage.
                      The flow output to the two cylinders powers each in the opposite direc-
                      tion. The right hand cylinder retracts as the left hand cylinder extends
                      and vice-versa.

                      The schematic shown is Fig. 61 is a typical conveyor swing cylinder
                      circuit. Always refer to the schematic in the parts book for your ma-
                      chine.

                      Fig. 61: Conveyor swing cylinder circuit


                      Note: Solenoid designations are CSL-R (conveyor swing left – rear so-
                      lenoid) and CSR-F (conveyor swing right – front solenoid).


   ______________________________________________________________
 A6474X356                 REV 03                             5.79

--- Page 17 ---
BI016888-03-EN

______________________________________________________ Hydraulic

                      Fig. 67: Dust sprays hydraulic circuit


                      Note: See water circuit in Water section of this chapter.


   ______________________________________________________________
 A6474X356                 REV 03                             5.89

--- Page 18 ---
BI016888-03-EN

__________________________________________________________ Water

                      Fig. 75: Dust-cooling left hand cutter motor circuit


 ______________________________________________________________
A6474X356             REV 2                                 5.99

--- Page 19 ---
BI016888-03-EN

_______________________________________________________ Electrical

                                Relays

                                ANSI defines a relay as “...an electrically controlled device that opens
                                and closes electrical contacts to affect the operation of other devices in
                                the same or another electrical circuit”. Relays are one of the most com-
                                mon auxiliary devices used in electrical circuits. They are used for
                                switching control circuits and for controlling light loads.

 instantaneous overload relay   The adjustable instantaneous overload relays, designated “OL1”, “OL3”,
                                “OL5”, and “OL7”, protect the miner from sudden surges of current.
                                While called “instantaneous” overloads the current sensing relays have
                                an adjustable start-up delay after which they operate as soon as the
                                motor current exceeds the preset level. The instantaneous overloads
                                have normally open contacts in the motors’ control circuit which close
                                when controlled voltage is applied. The instantaneous overloads protect
                                the motors from stall currents.

            time-delay relays   Time-delay relays (TDs) are used to cause a time lapse between the
                                time a circuit is energized and the time the contactors close in a circuit.

          thermally operated    The thermally operated overload relays are located in the main control-
              overload relay    ler assembly. They are used to protect the motors against long, steady
                                current overloads which are not strong enough to trip the instantaneous
                                overloads.

                                The heart of the thermally-operated overload relay is two thin sheets of
                                different kinds of metal bonded together. Heater strips, connected to a
                                line voltage through “CTs” ratio current reducing transformers, provide a
                                heat source for the thermally operated overloads. When a continuous
                                overload causes these strips to heat up, the bimetallic strips are heated.
                                As they are heated, the metal strips try to expand but, being different
                                types of metal they want to expand at different rates. Since the strips re
                                bonded together, they bend when heated and trip the overload relay,
                                causing a break in the protected circuit and shutting down the motor.

                                After the heater strips cool, the bimetallic strips return to their normal
                                position. When a thermal overload has been tripped, the fact is indicat-
                                ed by a visual trip indicator built into the relay unit. A selector switch
                                permits a tripped thermal overload relay to be reset automatically or
                                manually. The relays are normally adjusted for automatic reset opera-
                                tion.

  machine stop/e-stop switch    The machine stop/e-stop switch is located on the left side of the miner,
                                opposite the operator’s area. The contacts in the machine stop/e-stop
                                switch are normally closed. Depressing the large mushroom push but-
                                ton causes the moving contact to be pushed away from the stationary
                                contact, breaking the control circuit and de-energizing all the coils wired
                                in the main control circuit. The de-energized coils open all their con-
                                tacts, shutting down the miner except for the headlights. Once the but-
                                ton is released, the spring pushes the moving contact back against the
                                stationary contact so power is again available up to the control circuit.


   ______________________________________________________________
A6474X356                REV 03                              5.109

--- Page 20 ---
BI016888-03-EN

_______________________________________________________ Electrical

                                        Main controller case - inside swing panel

                                        The swing panel of the main controller case (Fig. 84) is accessed by
                                        opening the controller cover and then opening the swing panel. It is
                                        typically located on the left side of the machine, midway the tractor
                                        frame inside the crawler frame.

                                        IMPORTANT!
                                        This component location information is typical. Always verify
                                        component layout with the information in the parts book for your
                                        machine.

          vacuum contactor “CF”         Vacuum contactor “CF” is the forward contactor for the left and right
                                        gathering head motors.

          vacuum contactor “CR”         Vacuum contactor “CR” is the reverse contactor for the left and right
                                        gathering head cutter motors.

             overload relay “OL5”       “OL5” is an instantaneous overload relay for conveyor forward.

View the complete manual on HeyDownloads →