--- Page 1 ---
Operating Manual
                        Elektro-Hydraulic Control
                        - 14 Functions -
                        Doc. no.: 8154 051 000 BA 00


DBT GmbH
Industriestraße 1   Telefon: +49 (0) 23 06 / 709 - 0     Email: [email protected]
D-44534 Lünen       Telefax: +49 (0) 23 06 / 709 - 421   Internet: www.dbt.de

--- Page 3 ---
Conditions of operation

                         Conditions of operation
                         Use in conformance with specifications
                         The electrohydraulic control has been designed and manufactured
                         exclusively as part of the control system for shields. It is only al-
                         lowed to be used in connection with an electronic control unit, such
                         as for example a PM4.
                         Use the electrohydraulic control only as intended.
                         Intended uses are:
                         J The electrohydraulic control is combined with an electronic con-
                             trol unit − as for example a single control unit of type PM4. To-
                             gether they form a control unit designed to operate the functions
                             of a shield support. The two devices are part of an adjacent con-
                             trol system for electrohydraulic shield supports for use in under-
                             ground mining. The electrohydraulic control is an essential com-
                             ponent of this electrohydraulic shield control. Operation of the
                             functions is not allowed to be made direct by pressing the but-
                             tons of the electrohydraulic control, but via the respective single
                             control unit which must be located in one of the adjacent shields.
                             By means of this control unit the pilot valves of the control block
                             are actuated manually or program−controlled.
                         J Additionally, there are two exceptional circumstances under
                             which the control block also serves as direct "control unit":


                                                                                                          E
                             − emergency operation and


                                                                                                          DBT GmbH, Lünen 2004
                             − repair operation.
                             In these cases the individual functions of the electrohydraulic
                             shield support are executed direct at the pilot valve of the elec-
                             trohydraulic control. Thus, the functions of the shield can be op-
                             erated even if the single control unit is locked out or has failed −
                             but only in well−founded exceptions and under strict observance
                             of the special safety regulations of the mine operator for these
                             cases.

                         Unauthorized use
                         Uses which are not expressly stated as intended are regarded as
                         unauthorized uses and are not permissible.
                         Unauthorized use::
                         J Use of the electrohydraulic control as "control unit" to operate
                             the functions of the shield in normal operation.
                             Actuating the shields exclusively by pushing a button on the pilot
                             valve block is unauthorized use since operation of the shield
                             functions must be performed from an adjacent shield.
                         By unauthorized uses you endanger yourself and others. You
                         could be severely injured or even killed. Therefore only use the
                         electrohydraulic control as intended!
                         DBT does not accept any liability for the consequences of unautho-
                         rized uses.


                                                                  Electrohydraulic Control 14−Functions
2.4

--- Page 4 ---
Storage


                                                      Storage and transport
                                                      This chapter contains important information on the correct storage
                                                      and transport of the elektrohydraulic control.
                                                      Observance of the instructions and tips will increase the service life
                                                      of the elektrohydraulic control. You will also be able to carry out the
                                                      transport work quicker and more safely.
                                                      Careful attention to the points in this chapter will help you to simplify
                                                      your day−to−day work.

                                                      Storage
                                                      Storage of new equipment
                               corrosion protection   The surfaces of the equipment are provided with a temporary corro-
                                                      sion protection. If stored properly, the equipment parts will be pro-
                                                      tected for six months referred to the date of delivery.
                                                      Prior to delivery the hydraulically operated equipment will be tested
                                                      and operated at the DBT site using the anti corrosive and anti freez-
                                                      ing fluid HYDROCOR® CV50*). This fluid remains in the hydraulic
                                                      system for transport and a following short−time storage period.
                                                      HYDROCOR ® CV50 is freeze−proof down to − 40 degrees Celsius
                                                      and protects the metallic materials against corrosion.
                                                      HYDROCOR ® CV50 is equipped with a color indicator, which is re-
                                                      sponsive on the pH−value of the fluid. The color of the fluid will
E
DBT GmbH, Lünen 2004


                                                      change from "red" to "yellow" in case the pH−value drops. A yellow
                                                      colored fluid indicates insufficient corrosion protection.
                                                      For further particulars on the properties of HYDROCOR® CV50
                                                      please refer to the respective data sheet of the manufacturer.
                                       exposure to    Protect the equipment against direct exposure to sunlight.
                                          sunlight    Store the electrical equipment, electronic components, spare parts of
                                                      rubber or plastic − such as seals and hoses − and hydraulic fluids
                                                      only in closed rooms at temperatures of 15 °C to 25 °C.
                                    natural ageing    Even with proper storage, seals and hoses are subject to natural
                                                      ageing. A storage period of approx. two years is therefore recom-
                                                      mended for these parts.
                                  moisture and dirt   Protect all hydraulic elements during storage in a suitable manner
                                                      against the ingress of dirt and moisture. The connecting surfaces of
                                                      the hydraulic components must be protected against corrosion and
                                                      closed with blind plates. Hydraulic plug−type connections and the
                                                      connectors of the electric cables must be closed with suitable caps
                                                      or plugs.
                                short−term storage    During short−term storage (approx. 4 weeks) of equipment outdoors,
                                                      but at temperatures above freezing, electrical components need not
                                                      be removed. Such components must, however, be particularly pro-
                                                      tected against environmental influences, including high tempera-
                                                      tures, for example by suitable covers or sheathings for the controls
                                                      and by additionally covering the equipment.
                                 long−term storage    If the equipment is to be stored for more than 6 months, the cavities
                                                      in the hydraulic components must be completely filled with a pre-
                                                      serving fluid such as e.g. HYDROCOR® CV 50. This fluid must have
                                                      corrosion−protection properties and should be frost−proof within the
                                                      respective temperature range of the application. All ports must be
                                                      *)   HYDROCOR ® CV50 is a trade name of Theunissen, Chemische Fabriken
                                                           GmbH, Wuppertal / Germany


                       Doc. no.:8154 051 000 BA 00    VEVE / 01
                                                                                                                               3.3

--- Page 6 ---
Connections

                                                      Connections
                                                      The connection ports for the hydraulic lines are located on the rear
                                                      of the control valve block.
                                                      Fig. 15: Rear view of the electrohydraulic control


                                                                                 13 11     9       4       1       5       3       8


                                                                              14 12 10         6       2
                                                                                                                                       P
                                                                                                               T               7
                                                                                                                       3
                                                                                               SP


                                                      Hydraulic connections
                          large−volume consumers      connections:         5 x DN 20 socket, plug−type
                                                      marking:             3, 3, 5, 7, 8
E


                                                      flow rate:           max 400 l/min
DBT GmbH, Lünen 2004


                                                      application:         large−volume consumers


                            low−volume consumers      connections:         10 x DN 10 socket, plug−type
                                                      marking:             1, 2, 4, 6, 9, 10, 11, 12, 13, 14
                                                      flow rate:           max 80 l/min
                                                      application:         low−volume consumers


                         pressure supply, tank line   connections:         2 x DN 25 socket, plug−type
                         and accumulator cartridge                         1 x DN 20 socket, plug−type
                                                      marking:             P      − pressure supply, DN 25
                                                                           T      − tank line, DN 25
                                                                           SP     − accumulator cartridge socket, DN20
                                                      application:         pressure supply to the system,
                                                                           return line to the tank
                                                                           socket for accumulator cartridge


                       Doc. no.:8154 051 000 BA 00    VEVE / 01
                                                                                                                                           6.7

View the complete manual on HeyDownloads →