--- Page 1 ---
Operating manual
                           DBT - PMC®-R system
                                 VShield central control
                                 Version 10.56
                           Doc. no.: 1999 001 013 BA 00


Bucyrus DBT Europe GmbH
Industriestraße 1 Phone: +49 (0) 23 06 / 709 - 0    Email: [email protected]
D-44534 Lünen     Fax:   +49 (0) 23 06 / 709 - 1421 Web: www.bucyrus.com

--- Page 4 ---
Storage of data storage media


                                                                      Storage and transport
                                                                      This chapter contains important information on correct storage and
                                                                      secure transport of the PMC® components. Observance of the
                                                                      instructions and manuals will increase the service life and reliability
                                                                      of the system components. Reading this chapter thoroughly will
                                                                      help you to make your day-to-day work easier.
                                                                      Notice!
                                                                      Never store PMC® components and other electronic equipment
                                                                      outdoors under any circumstances.

                                                                      In this operating manual, the storage of data storage media, the
                                                                      creation of backup copies and the archiving of software are
                                                                      specifically addressed.
                                                                      Important!
                                                                      Every data storage medium and the corresponding
                                                                      reading/writing device might have its own information material
                                                                      and operating manuals which should be read carefully. These
                                                                      instructions only provide a few general tips for storing data
                                                                      storage media.


                                                                      Storage of data storage media
E


                                                                      If software is not copied via data lines, the following types of data
Bucyrus DBT Europe GmbH, Lünen 2008


                                                                      storage media are generally used:
                                                                      J Diskettes
                                                                      J CD or DVD
                                                                      J Exchangeable disk media (for example, external USB hard
                                                                          disk)

                                                                      Diskettes
                                                                      The following damage diskettes or the stored data:
                                                  damaging effects    J Dirt and dust
                                                                      J Magnetic fields
                                                                      J Sunlight
                                                                      J Heat (> 50 °C)
                                                                      J Cold (< 10 °C)
                                                                      J Moisture
                                                                      J Bending the diskette

                                                 best storage place   The best place to store diskettes is in plastic or cardboard sleeves
                                                                      in a dust- and dirt-free, lockable metal cabinet in an air-conditioned
                                                                      room.
                                                      not a durable   Diskettes can be stored for up to 5 years, depending on the storage
                                                   storage medium     place, but they can be very easily damaged and are therefore not
                                                                      to be considered to be a durable storage medium.


                                      Doc. no.: 1999 001 013 BA 00    VEVT / 01
                                                                                                                                              3.3

--- Page 5 ---
Installation

                                      Fig. 7:   Explosion-proof central computer MCU2


                                                                                      1                                       1

                                                                                                                                                 2


                                                2


                                                                                                                          6           7


                                                                4                                                                 4
                                                                                3
                                                         5
                                                                                                                                          3
E
Bucyrus DBT Europe GmbH, Lünen 2008


                                      1 = explosion-proof computer housing
                                      2 = housing cover with viewing window
                                      3 = terminal box
                                      4 = ports for SKK24 connectors (mouse, keyboard, server,...)
                                      5 = brass strip
                                      6 = fiber-optic cable port RxD
                                      7 = fiber-optic cable port TxD

                                                                          The USB stick can then be connected to the ExPC underground. To
                                                                          do this, the cover of the terminal box (3) must be opened. Behind
                                                                          that there is a USB cable port to which the USB stick can be
                                                                          connected.
                                                                          Important!
                                                                          Before opening the terminal box, the PC must be shut off.
                                                                          Before switching on again, the terminal box must be
                                                                          completely closed since otherwise there is no explosion
                                                                          protection.

                                                                          The installation can be started by double-clicking on the file
                                                                          setup.exe.

                                                                          Installation
                                                                          The “VShield” program is installed by carrying out the following
                                                                          instructions one after another.
                                                                          Procedure
                                                                           . Copy the files included in the scope of delivery to a folder of
                                                                               your choice on the hard drive.
                                       target folder for program file      . Start the “setup.exe” program.

                                      Doc. no.: 1999 001 013 BA 00        VEVT / 01
                                                                                                                                                     4.9

--- Page 6 ---
Editing the initialization file

                                                                     1   Send data to the “VLongwall” program.
                                                     Default value 0     Do not send any data.
                                                                         Example:
                                                                         CheckVLongwall=0
                                                   LoggingEnabled =      Saving received data in a log file
                                                                         The “VShield” program can save all received data in a log file.
                                                                         (see also SavePath parameter).
                                                                         The LoggingEnabled parameter can be assigned the following
                                                                         values:
                                                                     1   Writing in the log file is switched on.
                                                     default value 0     Writing in the log file is switched off.
                                                                         Example:
                                                                         LoggingEnabled=0
                                                       VShieldTrend      The program is notified here where the VShieldTrend program with
                                                                         which it communicates is stored.
                                                                         Example:
                                                                         VShieldTrend =
                                                                         C:\DBT\VCU\VShieldTrend\10_40__Build_2800\VShieldTrend.exe
E


                                                                         [languages]section
Bucyrus DBT Europe GmbH, Lünen 2008


                                                                         The desired display language can be entered in the [languages]
                                                                         section by commenting in and out. This corresponds with the
                                                                         VShield###.dll files described in the scope of delivery section. Only
                                                                         those languages can be selected whose abbreviation appears as
                                                                         the place holder “###” in the file names.
                                                                         Example:
                                                                         Esp for Spanish: enable_spanish = 1
                                                                         Deu for German: enable_german = 1
                                                                         Enu for English: enable_english = 1
                                                                         Further available options are:
                                                                         J Russian
                                                                         J Chinese
                                                                         J Czech


                                      Doc. no.: 1999 001 013 BA 00       VEVT / 01
                                                                                                                                             4.19

--- Page 7 ---
Changing windows

                               Fig. 24: Changing the sizes of various windows


                               When the cursor changes form at the edge of the window, one can
                               grab the edge of the window with the left mouse button and reduce
                               or enlarge the size of the window.
                               Menu management without mouse connection
                               If no mouse should be present, the central control can also be
                               operated completely using the keyboard.
                               Using the key combinations Alt together with the underlined letters
                               in menu names, the corresponding menu is opened. For example:
                               The Control menu is opened with the key combination Alt+t.
                               The Data recording menu is opened with the key combination Alt+z.
                               With the up or down arrow keys, the blue cursor can be moved up
                               or down.
                               With the left and right arrow keys, one can switch among the main
                               menus.
                               Once a menu item is selected with the mouse or arrow keys, this
                               can be opened by pressing the enter key.
                               Commands can also be directly executed by means of key
                               combinations. For example. one can go directly into the menu
                               “Input lines” with the key combination Ctrl+L. The key combinations
                               can each be found after the respective submenu items.


Doc. no.: 1999 001 013 BA 00   VEVT / 01
                                                                                                     5.7

--- Page 8 ---
SRB parameters

                               SRB parameters
Fig. 41: SRB parameters


                               Fig. 41 shows the global SRB parameters. There is also a tab for
                               local settings which can be selected analogously to the procedure
                               described above. Here, generally applicable safety and type
                               settings are made.
                               Important!
                               The shown parameters depend on the PMC®-R program to
                               which the VShield program is linked.


                               Water spray parameters
                               WGB = Walzengassenbedüsung
                               WSP = Water Spray Parameters
                               Fig. 42 shows the dialog window for the water spray parameters.
                               Fig. 42: WSP parameters


                               The individual parameters have different designations in the plow
                               and shearer programs:


Doc. no.: 1999 001 013 BA 00   VEVT / 01
                                                                                                   5.17

--- Page 9 ---
The View menu

                               J Support type (1 for standard), other numbers for other support
                                   types, such as face edge shield, segment shield, etc.
                               J Receive counter for correctly received data telegrams
                               J Data age in seconds
                               These specifications are displayed in the white areas in the upper
                               area of the screen. Underneath this follow a field for pressure and
                               path displays.
                               Fig. 60: Pull-down menu in the “Main text view” window

                                                       The individual displays on the main text
                                                       view can be activated/deactivated with the
                                                       mouse pointer. The switching status
                                                       (activated/deactivated) is indicated by a
                                                       checkmark. A displayed checkmark
                                                       indicates that it’s activated.
                                                       The “Flipper” parameter is listed twice.
                                                       The first position switches the flipper display
                                                       in [mm] on/off, and the second switches the
                                                       display in degrees [°] on/off.


                                                       Starting with the list position “ASQ” (red
                                                       arrow) a color-coded graphical display with
                                                       text information about the automatic
                                                       sequence is shown/hidden. Depending on
                                                       the shearer position, the activated automatic
                                                       functions are displayed in colors depending
                                                       on the status.


                               The yellow area shown in Fig. 59, page 5.26 (vertical stripes)
                               indicates the cursor position and can be changed with the “left” and
                               “right” cursor keys. This way, the display for the entire face can be
                               run through.
                               Color codes used for the automatic function displays:
                               Autosequence
                               Batch
                               Pull conveyor
                               Advance conveyor
                               Backpush (advance conveyor group)
                               PSA (positive set automatic)
                               Water spraying device
                               Shearer spraying
                               Shearer running batch
                               Automatic function ready
                               Automatic function activated


Doc. no.: 1999 001 013 BA 00   VEVT / 01
                                                                                                     5.27

--- Page 10 ---
The View menu

                                        Fig. 76: Feedback window for clearing error messages


                                              1             2
                                             Yes            No


1 = confirmation of clearing error messages
2 = cancel and keep the error list

                                        Telegram display
                                        With the button (4), “T.View” (see Fig. 71 page 5.34), an information
                                        window is called up in which one can call up the communication
                                        data for every single PMC-R or groups of PMC-R control units.
                                        Fig. 77: Telegram display


                                                  1     2


                                                                        5


                                   3


                                    4
                                              8                     7                      6

1 = selection button for sent or received telegrams for the face connection
2 = selection button for sent or received telegrams for the connection to another PC
3 = selection button for PMC-Rs
4 = group selection button (the respective column is selected via the selection button)
5 = list field for displayed telegrams
6 = close window
7 = maximum number
8 = start and stop buttons

                                        The telegram types (sent or received) are selected with “1” or “2”.
                                        In the button field (3), the PMC-R devices can be selected for which
                                        one wants to see the communication data (counting in hexadecimal
                                        numbers).
                                        The individual devices can be selected by column with the group
                                        selection buttons (4).
                                        Important!
                                        If one first selected individual devices and then clicks on the
                                        group selection button, the previously selected devices are
                                        deselected and the non-selected devices selected (inversion
                                        function of group selection buttons).

                                        The data of the activated devices are compiled in the list field (5)
                                        when the “Start” button (8) is clicked on.


Doc. no.: 1999 001 013 BA 00           VEVT / 01
                                                                                                               5.37

--- Page 11 ---
Central computer

                                                                     RAM memory        128 MB
                                                                     Data memory       1 GB Flash disk
                                                                     Hard disk         30 GB 2.5”
                                                                     Display 18”
                                                                     Resolution        1280:1024
                                                                     Operating system                      Windows 2000 PRO EN
                                                                     Input equipment keyboard with integrated mouse
                                                                     Master Control Unit MCU-2I */*/*/*/*
                                                                     Type key
                                                                     The following type key is used:
                                                                     MCU-2I */*/*/*/*
                                                                                        = blank = without Profibus subassembly
                                                                                        = P = Profibus subassembly installed
                                                                                        = blank = no I/O installed at port 4
                                                                                        = B = BIDIR with external power supply at port 4
                                                                                        = C = BIDIR with internal power supply at port 4
                                                                                        = T = TTY external PS port 4, transmitter 1/2, receiver 3/4
                                                                                        = U = TTY external PS port 4, transmitter 3/4, receiver 1/2
                                                                                        = V = TTY internal PS port 4, transmitter 1/2, receiver 3/4
                                                                                        = W = TTY internal PS port 4, transmitter 3/4, receiver 1/2
                                                                                        = blank = no I/O installed at port 3
                                                                                        = B = BIDIR with external power supply at power supply at port 3
                                                                                        = C = BIDIR with internal power supply at port 3
                                                                                        = T = TTY external PS port 3, transmitter 1/2, receiver 3/4
E
Bucyrus DBT Europe GmbH, Lünen 2008


                                                                                        = U = TTY external PS port 3, transmitter 3/4, receiver 1/2
                                                                                        = V = TTY internal PS port 3, transmitter 1/2, receiver 3/4
                                                                                        = W = TTY internal PS port 3, transmitter 3/4, receiver 1/2
                                                                                        = blank = no I/O at installed at port 2
                                                                                        = B = BIDIR with external power supply at port 2
                                                                                        = C = BIDIR with internal power supply at port 2
                                                                                        = T = TTY external PS port 2, transmitter 1/2, receiver 3/4
                                                                                        = U = TTY external PS port 2, transmitter 3/4, receiver 1/2
                                                                                        = V = TTY internal PS port 2, transmitter 1/2, receiver 3/4
                                                                                        = W = TTY internal PS port 2, transmitter 3/4, receiver 1/2
                                                                                        = blank = no I/O installed at port 1
                                                                                        = B = BIDIR with external power supply at port 1
                                                                                        = C = BIDIR with internal power supply at port 1
                                                                                        = T = TTY external PS port 1, transmitter 1/2, receiver 3/4
                                                                                        = U = TTY external PS port 1, transmitter 3/4, receiver 1/2
                                                                                        = V = TTY internal PS port 1, transmitter 1/2, receiver 3/4
                                                                                        = W = TTY internal PS port 1, transmitter 3/4, receiver 1/2


                                                                     A few additional identification markings can be added without
                                                                     influencing the intrinsic safety.
                                                                     Connections
                                                                     The peripheral lines are electrically connected by clearly labeled
                                                                     connectors.
                                                                     Commissioning, installation
                                                                     J The device may be put into operation in Category M2.
                                                                     J The power is connected via plug connectors. These may only
                                                                         be professionally installed.
                                                                     J Unused connectors are to be sealed.
                                                                     J The equipment is designed for the IP 54 protection type (when
                                                                         professionally attached to an external housing); in the event of
                                                                         harsh ambient conditions (e.g. sprayed water), the equipment
                                                                         must be additionally protected by the operator.


                                      Doc. no.: 1999 001 013 BA 00   VEVT / 01