Text Preview from This Manual
The text below was extracted from the visible preview pages to help you confirm the manual contents before download.
--- Page 1 ---
Operating manual
DBT - PMC®-R system
VShield central control
Version 10.56
Doc. no.: 1999 001 013 BA 00
Bucyrus DBT Europe GmbH
Industriestraße 1 Phone: +49 (0) 23 06 / 709 - 0 Email: [email protected]
D-44534 Lünen Fax: +49 (0) 23 06 / 709 - 1421 Web: www.bucyrus.com
--- Page 4 ---
Storage of data storage media
Storage and transport
This chapter contains important information on correct storage and
secure transport of the PMC® components. Observance of the
instructions and manuals will increase the service life and reliability
of the system components. Reading this chapter thoroughly will
help you to make your day-to-day work easier.
Notice!
Never store PMC® components and other electronic equipment
outdoors under any circumstances.
In this operating manual, the storage of data storage media, the
creation of backup copies and the archiving of software are
specifically addressed.
Important!
Every data storage medium and the corresponding
reading/writing device might have its own information material
and operating manuals which should be read carefully. These
instructions only provide a few general tips for storing data
storage media.
Storage of data storage media
E
If software is not copied via data lines, the following types of data
Bucyrus DBT Europe GmbH, Lünen 2008
storage media are generally used:
J Diskettes
J CD or DVD
J Exchangeable disk media (for example, external USB hard
disk)
Diskettes
The following damage diskettes or the stored data:
damaging effects J Dirt and dust
J Magnetic fields
J Sunlight
J Heat (> 50 °C)
J Cold (< 10 °C)
J Moisture
J Bending the diskette
best storage place The best place to store diskettes is in plastic or cardboard sleeves
in a dust- and dirt-free, lockable metal cabinet in an air-conditioned
room.
not a durable Diskettes can be stored for up to 5 years, depending on the storage
storage medium place, but they can be very easily damaged and are therefore not
to be considered to be a durable storage medium.
Doc. no.: 1999 001 013 BA 00 VEVT / 01
3.3
--- Page 5 ---
Installation
Fig. 7: Explosion-proof central computer MCU2
1 1
2
2
6 7
4 4
3
5
3
E
Bucyrus DBT Europe GmbH, Lünen 2008
1 = explosion-proof computer housing
2 = housing cover with viewing window
3 = terminal box
4 = ports for SKK24 connectors (mouse, keyboard, server,...)
5 = brass strip
6 = fiber-optic cable port RxD
7 = fiber-optic cable port TxD
The USB stick can then be connected to the ExPC underground. To
do this, the cover of the terminal box (3) must be opened. Behind
that there is a USB cable port to which the USB stick can be
connected.
Important!
Before opening the terminal box, the PC must be shut off.
Before switching on again, the terminal box must be
completely closed since otherwise there is no explosion
protection.
The installation can be started by double-clicking on the file
setup.exe.
Installation
The “VShield” program is installed by carrying out the following
instructions one after another.
Procedure
. Copy the files included in the scope of delivery to a folder of
your choice on the hard drive.
target folder for program file . Start the “setup.exe” program.
Doc. no.: 1999 001 013 BA 00 VEVT / 01
4.9
--- Page 6 ---
Editing the initialization file
1 Send data to the “VLongwall” program.
Default value 0 Do not send any data.
Example:
CheckVLongwall=0
LoggingEnabled = Saving received data in a log file
The “VShield” program can save all received data in a log file.
(see also SavePath parameter).
The LoggingEnabled parameter can be assigned the following
values:
1 Writing in the log file is switched on.
default value 0 Writing in the log file is switched off.
Example:
LoggingEnabled=0
VShieldTrend The program is notified here where the VShieldTrend program with
which it communicates is stored.
Example:
VShieldTrend =
C:\DBT\VCU\VShieldTrend\10_40__Build_2800\VShieldTrend.exe
E
[languages]section
Bucyrus DBT Europe GmbH, Lünen 2008
The desired display language can be entered in the [languages]
section by commenting in and out. This corresponds with the
VShield###.dll files described in the scope of delivery section. Only
those languages can be selected whose abbreviation appears as
the place holder “###” in the file names.
Example:
Esp for Spanish: enable_spanish = 1
Deu for German: enable_german = 1
Enu for English: enable_english = 1
Further available options are:
J Russian
J Chinese
J Czech
Doc. no.: 1999 001 013 BA 00 VEVT / 01
4.19
--- Page 7 ---
Changing windows
Fig. 24: Changing the sizes of various windows
When the cursor changes form at the edge of the window, one can
grab the edge of the window with the left mouse button and reduce
or enlarge the size of the window.
Menu management without mouse connection
If no mouse should be present, the central control can also be
operated completely using the keyboard.
Using the key combinations Alt together with the underlined letters
in menu names, the corresponding menu is opened. For example:
The Control menu is opened with the key combination Alt+t.
The Data recording menu is opened with the key combination Alt+z.
With the up or down arrow keys, the blue cursor can be moved up
or down.
With the left and right arrow keys, one can switch among the main
menus.
Once a menu item is selected with the mouse or arrow keys, this
can be opened by pressing the enter key.
Commands can also be directly executed by means of key
combinations. For example. one can go directly into the menu
“Input lines” with the key combination Ctrl+L. The key combinations
can each be found after the respective submenu items.
Doc. no.: 1999 001 013 BA 00 VEVT / 01
5.7
--- Page 8 ---
SRB parameters
SRB parameters
Fig. 41: SRB parameters
Fig. 41 shows the global SRB parameters. There is also a tab for
local settings which can be selected analogously to the procedure
described above. Here, generally applicable safety and type
settings are made.
Important!
The shown parameters depend on the PMC®-R program to
which the VShield program is linked.
Water spray parameters
WGB = Walzengassenbedüsung
WSP = Water Spray Parameters
Fig. 42 shows the dialog window for the water spray parameters.
Fig. 42: WSP parameters
The individual parameters have different designations in the plow
and shearer programs:
Doc. no.: 1999 001 013 BA 00 VEVT / 01
5.17
--- Page 9 ---
The View menu
J Support type (1 for standard), other numbers for other support
types, such as face edge shield, segment shield, etc.
J Receive counter for correctly received data telegrams
J Data age in seconds
These specifications are displayed in the white areas in the upper
area of the screen. Underneath this follow a field for pressure and
path displays.
Fig. 60: Pull-down menu in the “Main text view” window
The individual displays on the main text
view can be activated/deactivated with the
mouse pointer. The switching status
(activated/deactivated) is indicated by a
checkmark. A displayed checkmark
indicates that it’s activated.
The “Flipper” parameter is listed twice.
The first position switches the flipper display
in [mm] on/off, and the second switches the
display in degrees [°] on/off.
Starting with the list position “ASQ” (red
arrow) a color-coded graphical display with
text information about the automatic
sequence is shown/hidden. Depending on
the shearer position, the activated automatic
functions are displayed in colors depending
on the status.
The yellow area shown in Fig. 59, page 5.26 (vertical stripes)
indicates the cursor position and can be changed with the “left” and
“right” cursor keys. This way, the display for the entire face can be
run through.
Color codes used for the automatic function displays:
Autosequence
Batch
Pull conveyor
Advance conveyor
Backpush (advance conveyor group)
PSA (positive set automatic)
Water spraying device
Shearer spraying
Shearer running batch
Automatic function ready
Automatic function activated
Doc. no.: 1999 001 013 BA 00 VEVT / 01
5.27
--- Page 10 ---
The View menu
Fig. 76: Feedback window for clearing error messages
1 2
Yes No
1 = confirmation of clearing error messages
2 = cancel and keep the error list
Telegram display
With the button (4), “T.View” (see Fig. 71 page 5.34), an information
window is called up in which one can call up the communication
data for every single PMC-R or groups of PMC-R control units.
Fig. 77: Telegram display
1 2
5
3
4
8 7 6
1 = selection button for sent or received telegrams for the face connection
2 = selection button for sent or received telegrams for the connection to another PC
3 = selection button for PMC-Rs
4 = group selection button (the respective column is selected via the selection button)
5 = list field for displayed telegrams
6 = close window
7 = maximum number
8 = start and stop buttons
The telegram types (sent or received) are selected with “1” or “2”.
In the button field (3), the PMC-R devices can be selected for which
one wants to see the communication data (counting in hexadecimal
numbers).
The individual devices can be selected by column with the group
selection buttons (4).
Important!
If one first selected individual devices and then clicks on the
group selection button, the previously selected devices are
deselected and the non-selected devices selected (inversion
function of group selection buttons).
The data of the activated devices are compiled in the list field (5)
when the “Start” button (8) is clicked on.
Doc. no.: 1999 001 013 BA 00 VEVT / 01
5.37
--- Page 11 ---
Central computer
RAM memory 128 MB
Data memory 1 GB Flash disk
Hard disk 30 GB 2.5”
Display 18”
Resolution 1280:1024
Operating system Windows 2000 PRO EN
Input equipment keyboard with integrated mouse
Master Control Unit MCU-2I */*/*/*/*
Type key
The following type key is used:
MCU-2I */*/*/*/*
= blank = without Profibus subassembly
= P = Profibus subassembly installed
= blank = no I/O installed at port 4
= B = BIDIR with external power supply at port 4
= C = BIDIR with internal power supply at port 4
= T = TTY external PS port 4, transmitter 1/2, receiver 3/4
= U = TTY external PS port 4, transmitter 3/4, receiver 1/2
= V = TTY internal PS port 4, transmitter 1/2, receiver 3/4
= W = TTY internal PS port 4, transmitter 3/4, receiver 1/2
= blank = no I/O installed at port 3
= B = BIDIR with external power supply at power supply at port 3
= C = BIDIR with internal power supply at port 3
= T = TTY external PS port 3, transmitter 1/2, receiver 3/4
E
Bucyrus DBT Europe GmbH, Lünen 2008
= U = TTY external PS port 3, transmitter 3/4, receiver 1/2
= V = TTY internal PS port 3, transmitter 1/2, receiver 3/4
= W = TTY internal PS port 3, transmitter 3/4, receiver 1/2
= blank = no I/O at installed at port 2
= B = BIDIR with external power supply at port 2
= C = BIDIR with internal power supply at port 2
= T = TTY external PS port 2, transmitter 1/2, receiver 3/4
= U = TTY external PS port 2, transmitter 3/4, receiver 1/2
= V = TTY internal PS port 2, transmitter 1/2, receiver 3/4
= W = TTY internal PS port 2, transmitter 3/4, receiver 1/2
= blank = no I/O installed at port 1
= B = BIDIR with external power supply at port 1
= C = BIDIR with internal power supply at port 1
= T = TTY external PS port 1, transmitter 1/2, receiver 3/4
= U = TTY external PS port 1, transmitter 3/4, receiver 1/2
= V = TTY internal PS port 1, transmitter 1/2, receiver 3/4
= W = TTY internal PS port 1, transmitter 3/4, receiver 1/2
A few additional identification markings can be added without
influencing the intrinsic safety.
Connections
The peripheral lines are electrically connected by clearly labeled
connectors.
Commissioning, installation
J The device may be put into operation in Category M2.
J The power is connected via plug connectors. These may only
be professionally installed.
J Unused connectors are to be sealed.
J The equipment is designed for the IP 54 protection type (when
professionally attached to an external housing); in the event of
harsh ambient conditions (e.g. sprayed water), the equipment
must be additionally protected by the operator.
Doc. no.: 1999 001 013 BA 00 VEVT / 01