--- Page 1 ---
The Raymond ® Transtacker
Maintenance Manual
Model Serial No.
TRT TRT-03-00100 and up
Publication PDMM-0092A Issued: 30 September 2004
Publication PDMM-0092B Updated: 01 March 2005
Publication PDMM-0092C Re-Issued: 30 September 2006
Publication PDMM-0092D Updated: 01 August 2007
Publication PDMM-0092E Re-Issued: 20 September 2013
--- Page 3 ---
The Raymond ® Transtacker Maintenance Manual Service Information Documents List
Service Information Documents List
The following Service Information documents (RSBs, RPINs, and RSIs) have been incorporated into
this manual.
Use the blank rows below to log Service Information documents when they are added to this
manual.
Document Number Subject Date
RSB TRT-08-003 Solid State Control Handle Knobs Sticking December 3, 2008
RSB TRT-09-001 Overspeed Device Torque Limiter Interference April 15, 2009
RPIN TRT-09-R002 Upper Mast Limit Switch June 23, 2009
RPIN TRT-10-R001 Carriage Roller Inspection August 22, 2010
RSI TRT-13-001 Steer Motor and Steer Controller Change April 8, 2013
RSI TRT-13-002 Hoist Brake Fails to Release June 25, 2013
Publication PDMM-0092, Issued: 30 September 2004 Page Revised 9/20/13 xi
--- Page 4 ---
The Raymond ® Transtacker Maintenance Manual Section 2. Safety
Section 2. Safety
Publication PDMM-0092, Issued: 30 September 2004 2-1
--- Page 5 ---
The Raymond ® Transtacker Maintenance Manual Section 2. Safety
AC Electrical Safety
AC Electrical Safety
If the red lights on the operator display
and the AC power distribution
compartment light up, do not step out of
the truck or reach out to touch the
racking. Drive the truck out of the aisle
on battery power, or shut OFF the AC
power to the overhead conductor bar
system before dismounting from the
vehicle. Repair the ground loss before
placing the truck back in operation.
The voltage levels on this truck can be at
a potential of up to 600 volts AC above
ground. High voltage can cause serious
injury or be fatal. Always disrupt input
power, unless it is required, before
performing maintenance procedures.
If power is required to perform specific
procedures; follow good electrical
practices, applicable electrical codes,
and the contents of this manual.
Publication PDMM-0092, Issued: 30 September 2004 2-11
--- Page 6 ---
The Raymond ® Transtacker Maintenance Manual Section 3. Systems Overview
Hoist System
automatically reduce the voltage to B3 to 13 to pulses and applies them to an externally
16 percent of it's input voltage but holding B3 mounted resistor where the pulses are
energized at a lower power level and preventing dissipated as heat. This process is called
it from overheating. The B3 solenoid activates “Dynamic Braking.”
the hoist brake manual release plunger
mechanism that releases the hoist brake, and The Hoist Motor (MH) is located on top of the
allows the carriage to lower. The Tractor PLC gear reduction unit at the front of the truck. It
(NA) automatically toggles the DC Lowering is a 3-phase, 60 Hz, 30 Horsepower, 480 VAC
Contactor off after approximately one second. (typical) squirrel cage motor with an integral
This allows the hoist brake to re-apply and stop cooling fan. It is inverter duty rated. A
the carriage from lowering. This is necessary thermostat is encapsulated within the stator
because when the hoist brake remains released windings. This thermostat “opens” at
too long, the carriage will reach a high enough approximately 302°F (150°C) and causes the
lowering speed to engage the Drop-Stop VFI to reduce power output. This results in
mechanism. This prevents any further use of slower lift speeds until the motor cools
the Emergency DC Lowering feature until the sufficiently, allowing the thermostat to reset.
Drop-Stops are reset.
The Hoist Gear Reducer is mounted to the
The Line Reactor (LR) assembly is located in the foremost mast upright tube at the front of the
battery charger compartment at the front of the truck. It is a triple reduction, right angle drive,
truck. It is mounted directly underneath the helical bevel gearmotor that results in high
battery charger. The LR consists of three choke efficiency, quiet running, and high reliability
coils. One coil is located in each leg of the with high load carrying capacity. The gear
480 VAC power that is applied to the VFI. The ratios vary from 40:1 to 60:1 depending on the
LR functions to smooth out any variations in application. The oil capacity of the gearbox is
current, and to reduce any spikes that could approximately 8 to 9 gallons. The two hoist
potentially damage the VFI. cable take-up drums (right and left) are
mounted on the output shafts at the sides of
The Hoist Motor Controller (VFI) is located in a the gear reducer unit.
compartment at the front of the truck directly to
the right of the battery charger. The VFI is a The Hoist Lift Cables are two independent,
microprocessor controlled Variable Frequency oppositely wound cables, each having a
Inverter. In most North American applications, minimum safety factor of 6:1, that support
the VFI is typically powered with 480 volt the entire carriage assembly. These cables run
3-phase AC. The VFI rectifies the incoming AC from the cable take-up drums, over the mast
to approximately 650 VDC. The VFI uses sheaves, down and around the carriage
Insulated Gate Bipolar Transistor (IGBT) sheaves, then up to the equalizing cable anchor
inverter bridge circuitry along with a special bar. With the carriage fully lowered, two full
pulse-width modulation method with selectable wraps of cable should remain on each take-up
pulse frequency to steplessly control the speed drum.
of the 3-phase AC Hoist Motor (MH) without
regard to sudden changes in its connected load. The Equalizing Hoist Cable Anchor Bar is
Nominal lift and lower speed is 90 feet per located at the top rear of the mast. The pivoting
minute. arrangement makes sure that each cable
supports the load equally.
During lowering operations and periods of
deceleration, the Hoist Motor delivers energy The Drop-Stop system is a gravity operated
back into the VFI. This causes the 650 VDC link brake that stops the vertical descent of the
voltage to increase. To prevent this voltage carriage when its speed reaches 150% of the
increase from rising to levels high enough to rated lowering speed and/or a hoist cable
cause damage, the VFI contains a “Braking becomes slack. A centrifugal clutch, operated
Chopper” circuit that chops the overvoltage into by a sprocket and a chain extending the full
Publication PDMM-0092, Issued: 30 September 2004 3-9
--- Page 7 ---
The Raymond ® Transtacker Maintenance Manual Section 3. Systems Overview
Operator Displays
Operator Displays Operator Display (OD2)
Operator Display OD2 is a LED backlit liquid
Two operator displays are used on The crystal display for viewing text messages. It is
Raymond Transtacker.
located at the rear of the left control arm and
provides the following functions:
Operator Display (OD1) • Displays error codes.
• Supplies diagnostic information.
Operator Display OD1 is located at the end of
the right control arm, and provides the • Performs the Learn procedures for the
following information: Travel, Hoist, and Load Handler
• A steering display with 5 yellow LEDs and potentiometers.
1 green LED that indicate the position of • Performs Load Handler calibration
the steerable wheel. procedures (Fork Load Handler Only).
• A single green LED that, when lit,
indicates the load handler is centered or in
the ready for full speed travel position.
• A group of 4 red LEDs that, when lit,
indicate the Earth Ground Verification
Board was either not enabled or has
detected an unreliable connection between
the truck and the building AC power
system earth ground.
If the red lights on the operator display 3
Figure 3-4. OD2 Display
and the AC power distribution
compartment light up, do not step out
of the truck or reach out to touch the General Instructions
racking. Drive the truck out of the aisle
on battery power, or shut OFF the AC Operator Display (OD2) interfaces with the
power to the overhead conductor bar Carriage PLC (NB). OD2 displays error codes,
system before dismounting from the provides diagnostic information, and performs
vehicle. various “Learn” procedures. Press the Shift key
first, then press the appropriate Function key,
F5 through F8, for the action you want to
perform. Refer to “Analog Diagnostics / Learn
Procedures” on page 3-20 for details on the use
of each function key.
NOTE: It is important to note that the truck
must be powered up (key switch ON) for at
least seven to ten seconds before
performing “Learn” procedures. All
Learned values will be lost and all control
handle potentiometer neutral positions
must be relearned if the truck was not
powered up for the seven to ten second
time period.
3
Figure 3-3. OD1 Display
Publication PDMM-0092, Issued: 30 September 2004 3-19
--- Page 8 ---
The Raymond ® Transtacker Maintenance Manual Section 3. Systems Overview
Special Tools
Changing a Parameter
To access parameters, use the Menu Navigation
key to select PROGRAM. Submenus organize the
parameter list. Scroll through the list and press
the right arrow on the Menu Navigation Key to
enter the sub-menu. Parameters available are
shown in Table 3-4.
Table 3-4. Program Mode Adjustable Parameters
Nominal
Parameter Range Units Description
Setting
M3 THRT BRK 60 to 100 80 % Determines the “hardness” of the plugging when
transitioning from M4 to M3 (entering a slow flag).
M2 Max. Speed 0 to 40 35 % Sets maximum out of aisle speed.
M3 Max. Speed 0 to 30 25 % Sets maximum in-aisle creep speed for slow flag zone
or load handler not centered.
M4 Max. Speed 0 to 100 100 % Sets maximum in-aisle speed.
M2 THRTL MAP 20 to 80 50 % Determines the “hardness” of acceleration in Mode 2.
M4 THRTL MAP 20 to 80 50 % Determines the “hardness” of acceleration in Mode 4.
Publication PDMM-0092, Issued: 30 September 2004 3-29
--- Page 9 ---
The Raymond ® Transtacker Maintenance Manual Section 4. Scheduled Maintenance
Section 4. Scheduled Maintenance
Publication PDMM-0092, Issued: 30 September 2004 4-1
--- Page 10 ---
The Raymond ® Transtacker Maintenance Manual Section 4. Scheduled Maintenance
Every 180 Days or 1000 Deadman Hours (HD)
Every 180 Days or 1000
Deadman Hours (HD)
Every 180 Days or 1000 Deadman Hours (HD)
Perform all 60-day/250-hour checks, including daily checks, plus the following:
Item No.
See “Scheduled
Maintenance,
Lubrication, Component What to do
and Inspection
Points” on
page 4-14.
16 Hardware Check tightness of all hardware connecting wires and cables.
Check bolt torque every 1000 hours.
33 Lift Cables Lubricate. Clean and swab entire length with lubricant. See
“Lubrication Specification Chart” on page 9-5.
34 Carriage Cam Lubricate grease fittings. Apply two or three shots of lubricant at
Followers each point. See “Lubrication Specification Chart” on page 9-5.
Clean off old grease build-up.
35 Pulley Sheaves Check for binding or wobbling on axle shaft. Repair or replace faulty
(Upper and Lower) sheaves per maintenance procedure on page 7-268.
8 Drive Unit Check mounting bolt torque. (Refer to page 7-84, step 2.)
36 Pivot Points Check drop-stop linkage, AC collector linkage, door hinges, and so
on. Clean and apply a few drops of a lubricant, such as AeroKroil or
equivalent, to all pivot points. See “Lubrication Specification Chart”
on page 9-5.
Check hoist brake manual release linkage to emergency DC lowering
solenoid.
37 Steer Actuator Check mounting bolt torque. (Refer to page 7-34, step 3.)
(Motor) Mounting
Bolts
Fork Load Handler Only
51 Reach Motor Check friction disc. Adjust and/or replace per maintenance
Brakes procedures on page 7-221.
Clean vent holes with low compressed air.
Shuttle Load Handler Only
61 Shuttle Motor Check minimum disc thickness (3/32 in. or 2.3 mm).
Brake Check magnet air gap (0.045 to 0.100 in. or 1.1 to 2.5 mm).
62 Fail-Safe Brake Check air gap (0.008 to 0.012 in. or 0.203 to 0.304 mm).
(multiple shuttles
only)
54 Shuttle Chains Check for wear.
Publication PDMM-0092, Issued: 30 September 2004 Page Revised 9/20/13 4-11
--- Page 11 ---
The Raymond ® Transtacker Maintenance Manual Section 4. Scheduled Maintenance
Scheduled Maintenance, Lubrication, and Inspection Points
54
56
4lube-rch.pcx
Figure 4-9. Shuttle Gearbox Lubrication Points (view from underside of carriage)
Publication PDMM-0092, Issued: 30 September 2004 4-21
--- Page 12 ---
The Raymond ® Transtacker Maintenance Manual Section 5. Troubleshooting
Troubleshooting Procedure
GEN1: General Troubleshooting
GEN1: General Troubleshooting
Gather as much
information as you Eliminate unlikely
What is the problem?
can about the causes.
problem.
Where did it happen?
When did it happen?
What functions are affected?
Select and prioritize
What conditions trigger the problem? the most likely
causes.
Check each
Talk directly with the likely cause, using
Process
operator or foreman. the tests in this
manual.
Check all other
Operate the lift truck truck functions
yourself. before returning the
lift truck to service.
Using schematics
if necessary,
identify all
components which
could cause the
problem.
5GEN1.WMF
Publication PDMM-0092, Issued: 30 September 2004 5-9
--- Page 13 ---
The Raymond ® Transtacker Maintenance Manual Section 5. Troubleshooting
Fuses/Circuit Breakers
Fuses/Circuit Breakers
Test/Inspection
Examine for signs of overheating, discoloration,
cracking, or other physical damage.
To test a fuse, remove it from the vehicle or
isolate it from the electrical circuit by removing
all the connections from one side of the fuse.
Use a digital ohmmeter set on the lowest scale
and measure the resistance across the fuse.
The resistance should measure less than 1
ohm.
Fuse Locator Chart
Table 5-2. Fuse Identification, Location, and Function
Fuse Amps AC/DC Location Function
FU1 350 A DC Drive Motor Compartment Power Fuse, Travel
(Contactor Panel)
FU2 15 A DC Drive Motor Compartment Steering Fuse (S/N 230 and below)
(Tractor PLC Hinged* Panel)
FU3 15 A DC Drive Motor Compartment Steering Fuse (S/N 230 and below)
(Tractor PLC Hinged* Panel)
FU3 80 A DC Drive Motor Compartment Steering Fuse (S/N 231 and Up)
FU4 15 A DC Drive Motor Compartment Control Fuse (B+)
(Tractor PLC Hinged* Panel)
FU5 15 A DC Drive Motor Compartment Control Fuse, Travel Power (B–)
(Tractor PLC Hinged* Panel)
FU6 15 A DC Drive Motor Compartment DC Function Fuse (slo-blo) (B+)
(Tractor PLC Hinged* Panel)
FU7 15 A DC Drive Motor Compartment DC Function Fuse (slo-blo)
(Tractor PLC Hinged* Panel)
FU8 15 A AC AC Electrical Compartment Rotate and Reach Motor Controller Fuse
(Slide-out Panel) (slo-blo) (Fork Load Handler)
Shuttle Load Handler Enable Relay Fuse
(Shuttle Load Handler)
NOTE: * Tractor PLC Panel is not hinged on cold storage vehicles.
Publication PDMM-0092, Issued: 30 September 2004 Page Revised 9/20/13 5-19
--- Page 14 ---
The Raymond ® Transtacker Maintenance Manual Section 5. Troubleshooting
DC Lowering Troubleshooting
DC Lowering approximately 0.75 second intervals. The
contactor tips should also close and open
Troubleshooting at this rate. If this is not observed, use the
schematics in the Appendix section of this
manual to check for open conditions with
DC Lower Function Inoperative the DC Lowering Contactor (LC) coil and
associated wiring. Repair or replace as
1. Check for +24 VDC at the Carriage PLC necessary.
(NB) input terminal NB-I-1.5 with respect
to TS6-6, TS6-7, TS6-8 or other similar 5. If the desired results were obtained in step
ground point when the DC Lower/Retract 4, check for B+ across both the +BAT and
Switch (S17 on a Fork Load Handler +AUX terminals with respect to the –BAT
equipped truck or S18 on a Shuttle Load terminal on the Control Module (CM2).
Handler equipped truck) is activated. The This voltage should toggle ON and OFF at
corresponding green indicator LED for approximately 0.75 second intervals. If
NB-I-1.5 should be lit (ON). If +24 VDC is this is not observed, use the schematics in
measured and the LED does light, proceed the Appendix section of this manual to
to step 3. If +24 VDC is not measured and check the wiring and connections from
the LED does not light, check the S17 or CM2 to LC-1 and TS9-1. Repair or replace
S18 switch and associated wiring for as necessary. Check LC tips for wear,
continuity, poor connections, or damage. burning, or pitting. Clean or replace as
Repair or replace as necessary. necessary.
6. If the voltage to CM2 was correct, check
2. If +24 VDC was measured but the green
indicator LED for NB-I-1.5 is dark (OFF), the wiring and connections from the WHT
and BLK terminals on CM2 to the DC
replace the Carriage PLC (NB).
Lowering Solenoid (B3) for shorts, opens,
3. Check for approximately +24 VDC at the or damage. Repair or replace as necessary.
Tractor PLC (NA) output terminal
NA-Q-1.1 with respect to NA terminal M or 7. Check the resistance of the DC Lowering
other similar ground point when the Solenoid (B3). It should measure between
lowering switch on the carriage is 2 and 3 ohms. Replace as necessary.
activated. The corresponding output LED 8. The DC Lowering Solenoid (B3) requires
should also be lit (ON). If approximately approximately 16 amps to pull the plunger
+24 VDC is measured and the LED does full stroke and dropping to approximately
light, proceed to the next step. The voltage 2 amps after 0.5 seconds to hold the
and LED should toggle ON and OFF at plunger in. Use a clamp-on ammeter to
approximately 0.75 second intervals. If check these current values if necessary.
+24 VDC is not measured and the LED 9. Refer to the DC Lowering Solenoid (B3)
does not light, disconnect the wire at installation procedures on page 7-180 to
NA-Q-1.1 and retest. If the voltage and verify the mechanical adjustments are
LED status are now good, use the correct.
schematics in the Appendix section of this
manual to check for shorted conditions
with the DC Lowering Contactor (LC) coil,
DA1, and associated wiring. Repair or
replace as necessary. If the voltage and
LED status are still wrong or they fail to
toggle correctly, replace the Tractor PLC
(NA).
4. Check for approximately +24 VDC across
the DC Lowering Contactor (LC). This
voltage should toggle ON and OFF at
Publication PDMM-0092, Issued: 30 September 2004 Page Revised 9/30/06 5-29
--- Page 15 ---
The Raymond ® Transtacker Maintenance Manual Section 5. Troubleshooting
Symptom Tables
Possible Cause Action
Rotate Motor Controller (MC1) 1. Connect a digital voltmeter across the SIG
terminal (+) and the COM/EN terminals (–).
Operate the Load Handler Control Knob in both
the CW and CCW directions. The meter should
indicate voltage from 0 to +9.5 VDC and 0 to
–9.5 VDC depending on the direction of control
knob movement.
2. If this voltage measurement is observed, replace
MC1.
3. If this voltage measurement is not observed,
check the wiring and connections between MC1
and AD2.
4. Refer to the checks for the Load Handler Control
Potentiometer (VR4) if the wiring and connections
between MC1 and AD2 check good.
Load Handler Control Potentiometer (VR4) 1. Connect a digital voltmeter across the AD2
module terminals C+ (+) and C– (–). The voltage
should measure between +2.0 and +3.0 VDC with
the control thumb knob centered (neutral
position). This voltage is nominally set to +2.5
VDC.
2. Move the control thumb knob slowly to its
extremes and hold it there while observing the
meter for any erratic fluctuations. The voltage
measured at the extremes should measure
between +0.5 and +4.5 VDC (ignore minor
variations).
3. If these voltages are not observed, replace VR4.
4. If these voltage measurements are obtained,
replace the Analog/Digital Module (AD2).
5. If the problem still exists, replace the Carriage
PLC (NB).
Publication PDMM-0092, Issued: 30 September 2004 Page Revised 9/30/06 5-39
--- Page 16 ---
The Raymond ® Transtacker Maintenance Manual Section 5. Troubleshooting
Symptom Tables
Possible Cause Action
Reach Motor Controller (MC2) or the 1. Monitor the voltage across the output terminals
Shuttle Motor Controller (MC1) M1 and M2. The voltage should remain steady in
relation to the Control Knob position (ignore
minor variations). Maximum voltage is
approximately 90 VDC. The polarity depends on
the direction of rotation requested.
2. If the output voltage varies and the Control Knob
is held steady, check the input voltage across the
SIG and COM/EN terminals. Maximum voltage is
approximately 9.5 VDC. The polarity depends on
the direction of rotation requested.
3. If this voltage remains steady (ignore minor
variations), replace the Motor Controller (MC2) for
a Fork Load Handler equipped truck or MC1 for a
Shuttle Load Handler equipped truck. If the
voltage fluctuates erratically or intermittently,
refer to the VR6 checks for a Fork Load Handler
equipped truck. For a Shuttle Load Handler
equipped truck, perform the adjustment
procedure for the shuttle proximity switches on
page 7-178.
Troubleshoot the Proximity Switches using the
Schematics and the Shuttle Load Handler and
Proximity Switch Operation information beginning on
page 8-52.
Publication PDMM-0092, Issued: 30 September 2004 5-49
--- Page 17 ---
The Raymond ® Transtacker Maintenance Manual Section 5. Troubleshooting
Symptom Tables
Possible Cause Action
No Lift or Lower – Fuse FU15 1. Place the Main AC Disconnect Switch (S26) in the OFF
Open (down) position. Remove fuse FU15 from the truck and
test it for continuity. Replace the fuse if there is no
continuity.
2. If the fuse tests good, check the wiring and connections
from FU15-2 to the PC2 contactor, Circuit Breaker (CB1)
and the Line Reactor (LR) to the L3 terminal on the VFI.
3. Manually close the PC2 contactor tips. Check for
continuity between FU15-2 and the L3 terminal on the
VFI. Repair or replace components as necessary.
Hoist Brake Not Released — No 1. Use the Schematics in the Appendix to determine if +24
Fault Code 1 VDC is being applied across the Hoist Brake Contactor
Coil (BC).
2. If the voltage is not present, check the associated wiring
for continuity, shorts, or physical damage.