PDF Instruction Manual Cat QSB Series Rotary Screw Belt Drive Air Compressor - 862 KB

This instruction manual provides essential operating and maintenance information for the Cat Electric Rope Shovel's QSB Series Rotary Screw Belt Drive Air Compressor.

It covers proper startup, operation, and shutdown procedures, as well as routine service tasks.

Following these instructions is key to ensuring the reliability and longevity of this critical component.

PDF Viewer
Viewer loads when you scroll here
SHARE THIS MANUAL
Download the PDF Manual
WAWhatsApp fFacebook 𝕏X TGTelegram ✉Email
PDF viewer loading area

Text Preview from This Manual

The text below was extracted from the visible preview pages to help you confirm the manual contents before download.

--- Page 1 ---
BI619696


                        QSB Series
          Rotary Screw Belt Drive Air Compressor


                                      Instruction Manual


This manual contains important safety information and should be made available to
all personnel who operate and/or maintain this product. Carefully read this manual
before attempting to operate or perform maintenance on this equipment.


                                                     Manual No. 65001-RA


                                                   December 2001 Edition

--- Page 3 ---
BI619696


Section II - Description

Capacity Control System

As the motor starts driving the compressor rotors, air is      Auto Dual (Standard)
drawn in, compressed and discharged into the air/fluid
reservoir. When the air pressure in the air/fluid reservoir    The Auto Dual system offers two choices of controlling
exceeds the set point of the pilot valve (normally 100         the Quincy QSB/T™ Compressor:
PSIG), the valve opens and passes a controlled volume of
air to the inlet valve air cylinder.                           With the selector switch in the Continuous Run position,
                                                               the compressor operates continuously, matching air
           NOTICE!                                             demand as the differential pilot valve controls the position
    Other pressures are available optionally.                  of the inlet valve. When maximum system pressure is
                                                               reached, the pressure switch opens, venting the air/fluid
The air forces a piston to move within the cylinder,           reservoir and, although the compressor continues to run
closing the inlet valve. The compressor will continue to       unloaded, no air is compressed.
run, matching air demand with air delivery by constantly
adjusting the position of the inlet valve. The inlet valve     When Auto Dual is selected, the compressor will perform
regulates compressor capacity between 100% and nearly          as above, however, a solid state timer is activated when
0% of rated delivery.                                          the pressure switch contacts open. This timer is
                                                               adjustable within a ten (10) minute range. When the timer
When maximum pressure (typically 10 PSIG above                 reaches the end of its delay period, the compressor will
normal full load pressure) has been obtained in the air        automatically shut down and assume a standby mode.
system, complete compressor unloading occurs. The              Upon a drop in system air pressure, the pressure switch
pressure switch located in the control panel sends a signal    contacts close, restarting the compressor automatically.
to the control and the solenoid valve opens, venting the       The timer should be set, during unit start-up, for a
residual pressure from the blowdown valve. At the same         minimum of six (6) minutes.
time, control air from the reservoir check valve is directed
through the solenoid to the inlet valve air cylinder. The      During the unloaded/timing mode, if plant pressure
inlet valve is held in a closed position preventing the        should drop causing the pressure switch contacts to close,
intake of air into the compressor and serving as a check       the compressor will continue to operate, resetting the
valve preventing reverse air/fluid flow through the inlet      timer and instructing the inlet valve to reopen.
valve and air filter.


8                                            Quincy Compressor® - QSB/T™

--- Page 4 ---
BI619696


                                                                     Section IV - Operating Procedures

Stopping the Compressor - Normal Operation

Close the service valve to the plant air distribution                   NOTICE!
system. Allow the pressure to build within the reservoir        A flashing —— on the digit display, accompanied
and the compressor to fully unload. Turn selector switch        by an LED on the left, signifies a faulty sensor
to the “OFF” position.                                          (either the pressure transducer or the temperature
                                                                probe).
           NOTICE!
   Always close the service valve when the                   A fast blinking LED indicates that the labeled function
   compressor is not being used to prevent the               has been tripped; an overpressure condition or motor
   system’s air pressure from leaking back into the          overload or high air temperature (HAT) trip.
   compressor if the check valve leaks or fails.
                                                             A slow blinking LED indicates that the separator
                                                             differential pressure (DP) switch has been tripped.
Stopping the Compressor - Emergency
                                                             A steady LED, along with a message blinking on the
Press the emergency stop button or cut the power at the      display, indicates a service time-out. The controller is
main disconnect switch or panel.                             programmed with recommended service intervals on the
                                                             fluid filter and the air filter. These filters should be
                                                             checked and serviced when indicated.
Electronic Control Operation (optional)
                                                             Basic Controls
The decal below shows the control layout for the
electronic control panel. The primary controls are on the
                                                              1) MENU - scrolls through the set parameters as
right hand side of the panel, with the selected item being
                                                                 indicated by the LED lamps to the left, in the
displayed on the LED digits in the top window.
                                                                 following order:
                                                                  a) System pressure (default)
                                                                  b) Discharge temperature
                                                                  c) (Total) Running Hours - shows run followed by
                                                                     the hours in alternating form.
                                                                  d) Loaded Hours - shows load followed by the
                                                                     hours in alternating form.
                                                                  e) Separator Hours - shows SEPA followed by the
                                                                     hours in alternating form.
                                                                  f) *Air Filter Hours - shows AIr.f followed by the
                                                                     hours in alternating form.
                                                                  g) *Fluid Filter Hours - shows Flu.f followed by
                                                                     the hours in alternating form.
The LED lamps in a vertical column, show the selected
display parameter and/or any alarm conditions. On                 h) Fluid service/sample hours - shows FLu
applying system power the LED status lights will blink               followed by the hours in alternating form.
and the numeric display will show the version number of              (Total/Loaded LED)
the software code installed. The system is ready to run
when the Power and System pressure LED lamps are lit
                                                             *These have no associated LED indicators.
and the pressure is displayed in the numeric display.


                                            Quincy Compressor® - QSB/T™                                                19

--- Page 5 ---
BI619696


Section VI - Servicing

Parallel (Shafts are parallel; sheaves not in line)                        QSB/T 10-30 HP TENSIONING DATA

                                                                                          SPRING HEIGHT (IN.)   BELT TENSION (LBS.)
                                                                                             (REFERENCE)         PRIMARY FOCUS*
                                                                   HP     SPRING COLOR      MIN       MAX         MIN       MAX
                                                                   15         BLUE          5.9        6.1        6.0       7.0
                                                                   20         BLUE          5.8        6.0        6.5       7.5
                                                                   25       YELLOW          5.7        5.9        6.0       7.0
                                                                   30        GREEN          5.8        6.0        6.0       7.0
 1) To check, use straightedge or string near sheave               * Must have clearance under pin.
    centers.
 2) To correct, loosen sheave and relocate on shaft
    until all four points touch straightedge. Tighten
    sheave in position.

            NOTICE!                                              Belt tension should also be checked monthly on 40 and 50
     Never pry the belts into the sheave grooves. This           HP units with the jackbolt tensioning system. Reference
     can damage the belt cords and lead to belt                  the following table for the belt tension specifications on
     turnover, short life or belt breakage.                      these units. Adjust as necessary, per the instructions on
                                                                 page 33.

Tension Specifications
                                                                   QSB/T 40-50 HP BELT TENSION SPECIFICATIONS
Use belt tension tester (Quincy part # 142645) when
                                                                        *             **                 ***
checking and tensioning the belts. See page 31 for
instructions on proper use of the belt tension tester.
                                                                    NEW BELT     AFTER RUN-IN      RETENSION BELT
                                                                  TENSION (LBS.) TENSION (LBS.) (AT OR BEFORE) (LBS.)
The spring tensioning system used on 15 through 30 HP               10.5-11.5        10.0                8.5
units is designed to maintain proper belt tension.
However, it is recommended that belt tension be checked            * Applies only to new belts at time of installation.
monthly and confirmed to be within tension requirements           ** Run-in tension applies to belts after a 2 hour running period.
listed in the following table. If not, adjust per instructions   *** Belts must be retensioned at or before reaching this tension.
on page 32.


30                                            Quincy Compressor® - QSB/T™

--- Page 6 ---
BI619696


                                                                          Section VII - Compressor Fluids

QuinSyn XP

Effective on orders entered on June 1, 2000 and later,         Applications
Quincy Compressor® began offering QuinSyn XP, a
long life synthetic fluid. QuinSyn XP is the factory fill      QuinSyn XP is designed for applications where the fluid
for high pressure units (defined as units over 125 psig full   is exposed to elevated temperatures for extended periods
flow). QuinSyn XP replaces QuinSyn HP 68 as our high           of time. Fluid thermostat temperature settings can be
pressure fluid and is totally compatible with QuinSyn HP       elevated to assist in reducing water content in the fluid in
68 (the fluids can be mixed together with absolutely no        high humidity applications. Consult Quincy’s Service
problems). Aftermarket pail and drum orders for                Department before making thermostat changes.
QuinSyn HP 68 will be filled with QuinSyn XP.
                                                               Disposal
QuinSyn XP is a custom blended polyolester (POE) fluid
ideally suited for rotary screw air compressors. QuinSyn       QuinSyn XP is considered nonhazardous waste. Disposal
XP is an ISO 68 viscosity fluid with a 12,000 hour life at     of this fluid should be done in accordance with Local,
100 & 125 psig full flow under normal operating                State, and Federal regulations. Should condensate need to
conditions and 8,000 hours as a high pressure fluid (exact     be treated, Quincy’s QIOWA fluid/water separators are
fluid life is determined by the fluid sampling program).       required.
QuinSyn XP is the only fluid available with Quincy’s ten-
year airend warranty (see Blue Alert #566).                    Fluid Analysis Program

Typical Properties of QuinSyn XP                 ISO 68        QuinSyn XP will be analyzed similar to QuinSyn although
                                                               the primary concern is the total acid number (TAN).
  Viscosity @ 100°F ASTM D445                    60.0 cSt.     Supplemental “on site” TAN kits will be applicable to this
  Viscosity @ 210°F ASTM D445                     9.8 cSt.     fluid as well as QuinSyn PG.
  Viscosity Index ASTM D2270                        131
  Specific Gravity 60/60                            0.95                  NOTICE!
  Flash Point ASTM D92                             570°F          To maintain extended warranty compliance, fluid
  Fire Point ASTM D92                              645°F          samples of QuinSyn XP must be sent to Quincy
                                                                  Compressor® Fluid Analysis a minimum of every
                                                                  2,000 hours.


                                             Quincy Compressor® - QSB/T™                                                 41

--- Page 7 ---
BI619696


Section VII - Compressor Fluids

                                      FLUID PARAMETERS
                              QuinSyn PG, QuinSyn XP & QuinSyn Plus

Property         Units          Test Method           Fluid Type      New Fluid   Marginal   Unacceptable
Viscosity         cSt          ASTM D-445            QuinSyn PG        45-55       41,61     <41, >61 (1)
40°C                                                 QuinSyn XP        58-75       50, 85    <50, >85 (1)
                                                    QuinSyn Plus       42-51       38, 56    <38, >56 (1)
Acid No.      mg KOH/gm        ASTM D-947            QuinSyn PG         <0.2      0.7-0.9       >1 (1)
TAN                                                  QuinSyn XP         <0.2        3-4         >4 (1)
                                                    QuinSyn Plus        <0.2      1.7-1.9      >2.0 (1)
                                               ADDITIVE METALS
Barium           PPM         Plasma Emission         QuinSyn PG       375-550       150        <10 (1)
                                                     QuinSyn XP          0         5-20          >20
                                                    QuinSyn Plus         0         5-20          >20
Calcium          PPM         Plasma Emission              All            0         5-20          >20
Magnesium        PPM         Plasma Emission              All            0         5-20          >20
Molybdenum       PPM         Plasma Emission              All            0         5-20          >20
Sodium           PPM         Plasma Emission         QuinSyn PG          0         40-50        >100
                                                     QuinSyn XP          0         40-50        >100
                                                    QuinSyn Plus         0         5-20          >20
Phosphorus       PPM         Plasma Emission         QuinSyn PG          0         5-20          >20
                                                     QuinSynXP          <50        5-20           0
                                                    QuinSyn Plus         0         5-20          >20
Zinc             PPM         Plasma Emission              All            0        100-200       >200
                                                WEAR METALS
Silver           PPM         Plasma Emission              All            0         5-10          >10
Aluminum         PPM         Plasma Emission              All            0         5-10          >10
Chromium         PPM         Plasma Emission              All            0         5-10          >10
Copper           PPM         Plasma Emission              All            0         5-10          >10
Iron             PPM         Plasma Emission              All            0         5-10          >10
Nickel           PPM         Plasma Emission              All            0         5-10          >10
Lead             PPM         Plasma Emission              All            0         5-10          >10
Tin              PPM         Plasma Emission              All            0         5-10          >10
Titanium         PPM         Plasma Emission              All            0         5-10          >10
Vanadium         PPM         Plasma Emission              All            0         5-10          >10
                                                    OTHER
Silicon          PPM         Plasma Emission              All            0         10-15         >15
Water            PPM            Karl Fisher          QuinSyn PG        <2000          NOT REPORTED
                                                     QuinSynXP          <800          NOT REPORTED
                                                    QuinSyn Plus        <800          NOT REPORTED
Antioxidant       %                HPCL                   All         95% min.        NOT REPORTED


 (1) The fluid will be condemned based on these parameters.


52                                      Quincy Compressor® - QSB/T™

--- Page 8 ---
BI619696


                                                           Section VIII - Troubleshooting

Symptom/Probable Causes:                        Corrective Action:
Premature Belt Failure:

BROKEN BELTS:
OBJECT FALLING INTO DRIVE                       PROVIDE ADEQUATE GUARDS OR DRIVE
                                                PROTECTION.

BELTS FAIL TO CARRY LOAD FOR NO VISIBLE
REASON:
DAMAGED TENSILE MEMBER                          FOLLOW CORRECT INSTALLATION PROCEDURE.

WORN SHEAVE GROOVES                             CHECK GROOVES FOR WEAR. REPLACE SHEAVES
                                                AS NECESSARY.

CENTER DISTANCE MOVEMENT                        CHECK DRIVE FOR CENTER DISTANCE MOVEMENT
                                                DURING OPERATION.

EDGE CORD FAILURE:
MISALIGNMENT                                    REALIGN AND RETENSION DRIVE.

DAMAGED TENSILE MEMBER                          FOLLOW CORRECT INSTALLATION PROCEDURE.

V-Belts Turn over or Come Off Drive:

FOREIGN MATERIAL IN GROOVES                     PROVIDE ADEQUATE GUARDS OR DRIVE
                                                PROTECTION.

MISALIGNMENT                                    REALIGN AND RETENSION DRIVE.

WORN SHEAVE GROOVES                             REPLACE SHEAVES.

DAMAGED TENSILE MEMBERS (BELTS PRIED ON)        FOLLOW CORRECT INSTALLATION PROCEDURE.
MISMATCHED BELT SET                             INSTALL NEW MATCHED BELT SET. (DO NOT MIX
                                                OLD AND NEW BELTS.)


Belt Stretches Beyond Available Take-up:

MISALIGNMENT                                    REALIGN AND RETENSION DRIVE.

DEBRIS IN SHEAVES                               CLEAN SHEAVES.

BROKEN TENSILE MEMBER OR CORD DAMAGE            REPLACE ALL BELTS.

MISMATCHED BELTS                                INSTALL NEW MATCHED BELT SET. (DO NOT MIX
                                                OLD AND NEW BELTS.)


                                  Quincy Compressor® - QSB/T™                               63

--- Page 9 ---
BI619696


Appendix B - Technical Data

QSB/T 15

     Full Load Operating Pressure                          psig                   100                  125
     Maximum Operating Pressure                            psig                   115                  140
     Minimum Operating Pressure                            psig                    75                   !
     Maximum Ambient Operating Temperature                  °F                    110                   !
     Minimum Ambient Operating Temperature                  °F                     35                   !
     Compressor Drive Motor                                HP                      15                   !
     Full Load Drive Motor HP                              BHP                    16.0                 15.6
     Unloaded Drive Motor HP                               BHP                    4.32                  3.9
     Drive Motor Service Factor                                                   1.15                  !
     Drive Motor Speed                                    RPM                    1770                   !
     Rotor Diameter                                        mm                    127.5                  !
     Male Rotor Speed                                      rpm                   1279                  1036
     Female Rotor Speed                                    rpm                    853                  691
     Rotor Tip Speed                                      m/sec.                 8.54                  6.92
     Inlet Capacity                                       acfm                     62                   48

     Aftercooling
     Heat Rejection:      Fluid Cooler                   BTU/min.                 577                  563
                          Aftercooler                    BTU/min.                 109                  91
     Aftercooler Approach (standard conditions)              °F                    8                    !
     Maximum Allowable Static Backpressure                in./H2O                0.125                  !
     Fan Flow                                               cfm                  2126                   !

     Water-cooled Cooling
     (Consult factory for water temperatures under 50°F or over 90°F and for water/glycol cooling systems.)
     Recommended Inlet Water Pressure                       psig                40-100                  !
     Aftercooler Approach to Cooling (water temperature)     °F                   15                    !
     Water Flow with Aftercooler at:    50°F                gpm                   1.1                   !
                                        70°F                gpm                   1.5                   !
                                        90°F                gpm                   2.6                   !

     Compressor Fluid
     Total Fluid Capacity                                 gallons                3.8                    !
     Reservoir Fluid Capacity                             gallons                2.5                    !
     Fluid Flow                                            gpm                   8.4                    9.3
     Typical Fluid Carryover                               ppm                   3-5                    !
     Normal Airend Discharge Temperature                    °F                 175-195                  !

     Sound (at 1 meter) (Base/Tank)
     Unenclosed (AC/WC)                                   dB(A)                  76/76                  !
     Standard Cabinet (AC/WC)                             dB(A)                  73/76                  !
     Low Sound Cabinet (AC)                               dB(A)                  67/69                  !


74                                         Quincy Compressor® - QSB/T™