PDF Electrical Technical Manual Cat Bucyrus 30MB3 - 2 MB

This specialized technical manual focuses on the electrical systems of the Cat Bucyrus 30MB3 mining machine.

It provides detailed wiring diagrams, component locations, and troubleshooting procedures.

Electricians and technicians will find this guide indispensable for diagnosing and resolving electrical issues efficiently.

Ensure the safety and reliability of your equipment's complex electrical systems with this factory manual.

PDF Viewer
Viewer loads when you scroll here
SHARE THIS MANUAL
Download the PDF Manual
WAWhatsApp fFacebook 𝕏X TGTelegram βœ‰Email
PDF viewer loading area

Text Preview from This Manual

The text below was extracted from the visible preview pages to help you confirm the manual contents before download.

--- Page 1 ---
BI620101


Β© Bucyrus
All Rights Reserved


       BUCYRUS                      R


                      Technical Manual

--- Page 3 ---
BI620101


                                                                                     Bucyrus Australia

                                    Delta SBD 30MB3 Electrical Manual


Main Chassis


                            CONVEYOR
                           PIVOT POINT


                                                                         GATHERING HEAD PIVOT POINT

                                                                    CUTTING HEAD PIVOT POINT
                                                                         GATHERING HEAD PIVOT POINT


          HYDRAULIC TANK


                                                                        GATHERING HEAD
                                                                        PIVOT POINT


The main chassis of the machine is a robust box-type structure of high-strength steel construction that
provides the following:


Mounting of the RH and LH crawler tracks and their independent drive systems and take-up
provisions.


β€’   Independent pivots for mounting the cutting head and gathering head and conveyor components
    and their associated hydraulic cylinders for articulation.
β€’   An integral hydraulic oil tank along with two electric motor/hydraulic pump assemblyβ€˜s and
    associated valves and piping.
β€’   A rear stabiliser and its articulating hydraulic cylinder for improving leverage forces during shear-
    down in the cutting sequence.
β€’   Mounting provisions for all major electrical system components and their associated wiring.


December 2009                                     Page 8 of 22                      Manual No. M01342

--- Page 4 ---
BI620101


                                                                                 Bucyrus Australia

                                    Delta SBD 30MB3 Electrical Manual


Bolting, Mining and Maintenance Modes

Bolting, Mining and maintenance modes have been fitted to the 30MB3 Miner and can be selected by
operating a diversion valve as per its tagging, this valve is mounted upon the Right Hand side of the
Miner beside the rib drilling rig.

The selections for the diversion valve are as follows:

Mining Mode              -       Raise the handle to the top position
Maintenance Mode         -       Move the handle to the centre position
Bolting Mode             -       Lower the handle to the lowest position


December 2009                              Page 18 of 22                        Manual No. M01342

--- Page 5 ---
BI620101


Bucyrus Australia

                                  Delta SBD 30MB3 Electrical Manual


3.   Isolate and secure energy sources

     β€’   Isolate primary isolator in an approved manner or using site procedures and/or
         manufacturers recommended instructions e.g., operate whole current isolator, remove plug,
         close valve etc. Shedding of loads prior to operating primary isolator may need to be
         considered in some instances.
     β€’   Isolate or secure/control all secondary energy sources. For example:
         - bleed off stored hydraulic or pneumatic pressure from pressure vessels, accumulators
              etc,
         - Release stored energy such as springs, conveyor belt tension, etc.
         - secure/barricade/chock elevated equipment or material hang-up in chutes, truck bodies
              etc
         - Chock machinery and equipment to prevent unplanned movement.
     β€’   Do not use auxiliary devices for isolation e.g., push buttons, control circuit devices,
         emergency stop buttons, key-switches, conveyor lanyards, etc. except where these remote
         isolator devices control an approved (to relevant Australian Standard) whole of current
         isolation device e.g. Motorised lanyard controls on conveyors to AS1755.

4.   Apply Personal Danger Tags / Locks, or Permit Danger Tags / Locks

     β€’   A Personal Danger Tag or lock is to be placed on the appropriate isolation point/s by a
         competent person.
     β€’   In the case of a permit:
         - a Permit Danger Tag / Lock is to be placed on the relevant isolation point/s by the
              Authorised Isolator after the Permit Holder has raised the appropriate permit
         - All members of the work party shall sign onto, or attach their Personal Danger Tag or
              lock to the appropriate permit after checking the work they are performing is covered by
              the Permit.
     β€’   Any visitor requiring to place a Personal Danger Tag or lock or sign onto a permit can only
         do so under direct supervision of a competent person or Permit Holder

     NB Depending on the circumstances, it may be necessary to reverse steps 4 and 5 e.g. When
     access to switchboards is necessary for verification purposes and a tag or lock will prevent
     entry.

5.   Verify the effectiveness of the isolation

     All isolations must be checked to verify the isolation has been effective by:
     β€’ Testing the test equipment is in good operating condition and is set to correct scale eg.
          Pressure gauges, non-contact voltage detector, multi-meters etc
     β€’ Checking the operation of test equipment before and after isolation
     β€’ Test the isolation has been effective by:
          - Checking for the presence of voltage for electrical isolations
          - Attempting to start the equipment e.g. mobile equipment/machinery
          - Opening valves in pipelines
          - Confirming secondary energies are secured e.g. Chocks etc.
     Check for test methods that may have been developed and approved for use for various
     isolations.


Manual No. M01342                                Page 5 of 9                       December 2009

--- Page 6 ---
BI620101


                                                                                    Bucyrus Australia


                               Delta SBD 30MB3 Electrical Technical Manual


Control and Light Circuit Breakers

The control and lights breaker handle is a thin lever located on the top right hand side of the
flameproof Main Control Case, which is on the left hand side of the machine.

The lever is pushed in to turn both circuit breakers ON and pulled out to turn circuit breakers OFF.

If the machine is powered and these circuit breakers are ON, the green 110V Control LED indication
light should be indicating healthy, behind the viewing window on the Main Control Case.

Traction AC Circuit Breakers
The Traction AC Circuit Breakers are located in the flameproof Main Control Case and operated via
the operating handle located on the front right hand side on the Main Control Case.

These isolate the AC power to the SCR Traction Drive Units. The circuit breakers are switched on by
moving the handle to the left. If a circuit breaker has tripped it must be reset by turning the handle
fully to the OFF position before it can be turned back on.

Whenever working on the traction, setting conveyor stops or head stops ensure both circuit breakers
are opened and operator handle tagged.


               NOTE:            This circuit breaker must be open to operate in
                                maintenance mode


                                                                                  Control & Lights Circuit
                                                                                      Breaker Lever


                                                                                 Traction Circuit
                                                                                 Breakers Handle


December 2009                             Page 5 of 14                        Manual No. M01342

--- Page 7 ---
BI620101


 30MB3 ELECTRICAL
TECHNICAL MANUAL

            SECTION 4
  GENERAL ELECTRICAL

--- Page 8 ---
BI620101


 30MB3 ELECTRICAL
TECHNICAL MANUAL
             SECTION 5
ELECTRICAL COMPONENT
              LAYOUTS

--- Page 9 ---
BI620101


                                                                             Bucyrus Australia


                          Delta SBD 30MB3 Electrical Technical Manual


Swing Panel Front Components


       No.   Component                                                   Labelled      Qty
        1    MTL Zener Barrier for Siren                                     Z1         1
        2    24V dc Power Supply                                            PS1         1
        3    50mA Control Fuses                                           F4 & F5       2
        4    Banshee Siren Auxiliary Relay                                   BS         1
        5    Side Lights Auxiliary Relay (Area Lights)                      SLR         1
        6    Rear Lights Auxiliary Relay (Not Used)                         RLR         1
        7    Traction Earth Leakage Auxiliary Relay                        TELR         1
        8    Front Lights Auxiliary Relay (Headlights)                      FLR         1
        9    Lights Dimmer Auxiliary Relay (Headlights)                     LDR         1
       10    Machine Voltage Analogue Converters                        C1, C2 & C3     3
       11    110V 3 Phase Control Circuit Breaker                           CB6         1
       12    LED Indication Panel                                                       1
       13    Relay I/O Module A                                          LAP00391       1
       14    Relay I/O Module B                                          LAP00522       1
       15    Control System Power Supply Module                          LAP00395       1
       16    Processor Control Hub                                       LAP00418       1
       17    Traction Fibre Optic Interface Module                       LAP00565       1
       18    Thermistor Module                                           LAP00394       1
       19    RS422/RS232 Data Converter for CH4 TX9042                  Dwg 509021      1
       20    MTL Zener Barrier for Methane Cct                          Dwg 509020      1


December 2009                       Page 11 of 16                        Manual No. M01342

--- Page 10 ---
BI620101


                                                                                      Bucyrus Australia


                                 Delta SBD 30MB3 Electrical Technical Manual


Power Supply Module
The 110/24 V DC Power supply module supplies 24V dc to all radio modules excluding the I.S. Solenoid
Driver. It is complete with (2) relay outputs which are used to interrupt the pilot (earth continuity) circuit from
the DCB to the miner when an inadvertent operation is detected by the control system or a Pilot Trip function
is activated by the operator on the remote control transmitter.

Inclinometer
The inclinometer is mounting within its own flameproof enclosure and is mounted under a small cover behind
the headlights on the cutter boom.

The inclinometer is used to indicate the cutting head height. The top and bottom cutting heights are
referenced to the horizontal zero position. You will not be able to shear beyond these limits unless boom
override mode is enabled.

To override the Inclinometer with the pumps running, using the transmitter operate the [SHIFT] then TRAM 3
and TRAM 4.

Override will stay on until the pumps are turned off.

Traction Module
The traction module is mounted on the front of the swing panel in the main control case.

The traction module communicates with the hub via a fibre optic CAN link and then interfaces to the SCR
traction drives via a RS 484 link that loops two the two drives. The power supply is 24V from the control
system.

Graphics Display Screen
This graphics display screen is located behind the viewing window on the display enclosure and provides the
operator/tradesman with fault information, machine modes and performance information.

The graphics display screen is connected directly to the processor control hub via a display communications
port. This is connected via a designated screen cable between the main control case and the display
enclosure.

The intrinsically safe hardware consists of:

I.S. Solenoid Module
The module is located in the stainless steel solenoid junction box mounted beside the main solenoid valve
bank.

The I.S. Solenoid Module is complete with:
a)    (18) I.S. digital inputs
b)    (14) I.S. proximity inputs
c)    (22) I.S. solenoid outputs

The solenoid module is supplied by a Forced Potato 12V 2A I.S. power supplied which is mounted inside the
top compartment of the display enclosure.

A display on the front of the solenoid drive indicates if the I.S. supply is on and communicating with the hub.


December 2009                               Page 5 of 21                         Manual No. M01342

--- Page 11 ---
BI620101


                                                                                 Bucyrus Australia


                            Delta SBD 30MB3 Electrical Technical Manual


I.S. Solenoid Module

12V dc I.S Solenoid Board

A18 - V35 Female 34 Pin

                                                               Wire
    Pin         Schematic               Name                                        Type
                                                             Number
 A18-A       SOL_5            Plow Out                      605           12V I.S. Solenoid +
 A18-B       SOL_11           Conveyor Raise                611           12V I.S. Solenoid +
 A18-C       SOL_2            Cutter Head Lower             602           12V I.S. Solenoid +
 A18-D       SOL_8            Spare
 A18-E       SOL_4            Cutter Head Retract           604           12V I.S. Solenoid +
 A18-F       SOL_10           Stab Jack Lower               610           12V I.S. Solenoid +
 A18-H       SOL_1            Cutter Head Raise             601           12V I.S. Solenoid +
 A18-J       SOL_7            Spare
 A18-K       SOL_3            Cutter Head Extend            603           12V I.S. Solenoid +
 A18-L       SOL_9            Stab Jack Raise               609           12V I.S. Solenoid +
 A18-M       NC
 A18-N       SOL_6            Plow In                       606           12V I.S. Solenoid +
 A18-P       SOL_ 12          Conveyor Lower                612           12V I.S. Solenoid +
 A18-R       SOL_13           Conveyor Swing Right          613           12V I.S. Solenoid +
 A18-S       NC
 A18-T       SOL_14           Conveyor Swing Left           614           12V I.S. Solenoid +
 A18-U       SOL_15           Apron Raise                   615           12V I.S. Solenoid +
 A18-V       SOL_16           Apron Float                   616           12V I.S. Solenoid +
 A18-W       NC
 A18-X       SOL_17           Water Sprays                  617           12V I.S. Solenoid +
 A18-Y       SOL_18           Traction Brake                618           12V I.S. Solenoid +
 A18-Z       SOL_19           Left East / West              619           12V I.S. Solenoid +
                              Conveyor Fwd
 A18-AA      NC
 A18-BB      SOL_20           Right East / West             620           12V I.S. Solenoid +
                              Conveyor Fwd
 A18-CC      NC
 A18-DD      SOL_21           Left East / West              621           12V I.S. Solenoid +
                              Conveyor Rev
 A18-EE      NC
 A18-FF      SOL_22           Right East / West             622           12V I.S. Solenoid +
                              Conveyor Rev
 A18-HH      NC
 A18-JJ      SOL_23           Spare                                       12V I.S. Solenoid +
 A18-KK      NC
 A18-LL      SOL_24           Spare                                       12V I.S. Solenoid +
 A18-MM      OV               12V dc I.S. Negative          0VIS          Power Supply
 A18-NN      12V              12V dc I.S. Positive          401           Power Supply


December 2009                         Page 15 of 21                         Manual No. M01342

--- Page 13 ---
BI620101


                                                                                  Bucyrus Australia


                               Delta SBD 30MB3 Electrical Technical Manual


Graphic Display Screens
The display screen is located on the right hand side of the machine in the flameproof display enclosure. This
provides the operator and tradesmen with fault information, machine modes and performance information.

Navigation Functions on Transmitter
The main machine display can be changed using the new Navigation System. To enter the radio system
Navigation mode the following steps must be followed.

1.    Press [SHIFT] and [MENU] (WATER switch) and hold for approx 2 seconds until screen heading
      flashes.

2.    Press [SHIFT] and [NAV] (CON left or right) to move through consecutive screens until the desired
      page is reached. A password is required for pages above page 99.

3.    Alternatively you can access the desired page by using the Blue numbers on the transmitter. To
      access page 201 press switches 2 (STAB DOWN), then 0 (FAN OFF), then 1 (TRAM 2-3), then #
      (CON UP). This will then open page 201 Remote Console.

4.    Screens can also be accessed by pushing the screen scroll button on the front of the display
      enclosure. This provides access to screens 1 to 20 and 99 only, all other screens require password to
      access. Optional – not fitted to all machines.


December 2009                             Page 3 of 45                       Manual No. M01342

--- Page 14 ---
BI620101


                                                                                       Bucyrus Australia


                                 Delta SBD 30MB3 Electrical Technical Manual


I/O Monitor – Inputs 1 of 5 (110V Inputs)


This I/O Monitor – Inputs 1 of 5 screen is Page 10 on the display screen menu. It displays the status of the
110V inputs connected to the I/O Modules A and B.

If a device input is closed (asserted/active), then it is displayed with a yellow button next to it on the screen.

If a device is open (non asserted or de-active), then no colour is shown next to it.


December 2009                              Page 13 of 45                          Manual No. M01342

--- Page 15 ---
BI620101


                                                                                   Bucyrus Australia


                               Delta SBD 30MB3 Electrical Technical Manual


SCR Drive Monitor


This SCR Drive Monitor screen is Page 20 on the display screen menu. It displays the following information
from both the left and right SCR traction drive power modules:

β€’     DC Motor Voltages
β€’     DC Motor Currents
β€’     DC Current Limits
β€’     Motor Armature No Volts
β€’     Motor Reversed Polarity
β€’     Motor Armature No Current
β€’     Drive Internal Error
β€’     Drive Forward Rev Error
β€’     Drive Reverse Rev Error
β€’     Drive Over Temperature

The voltage and current will give an actual voltage and current readout.

The other outputs will be either β€œ0” or β€œ1”. With a β€œ1” indicating that that output function is on and the β€œ0”
being off.

The voltages should be equal when observing both motor trends but the current can vary depending on the
load required for each track.


December 2009                            Page 23 of 45                        Manual No. M01342

--- Page 16 ---
BI620101


                                                                                  Bucyrus Australia


                               Delta SBD 30MB3 Electrical Technical Manual


Setup 5 of 10 – Inclinometer


The Setup 5 of 10 – Inclinometer is Page 108 on the display screen menu and this screen includes:

β€’     Roof Limit – Is the height of heading that is required to be cut.
β€’     Floor Limit – Is the lower height that the Shear Down function is inhibited.
β€’     Boom Horizontal Radians – This is the raw data received from the Inclinometer.
β€’     Top Cutting Overshoot – Is the distance the solenoid is de-energised from the roof to ensure the cutter
      stops at the required height while cutting coal.
β€’     Top Air Overshoot – Is the distance the solenoid is de-energised from the roof to ensure the cutter
      stops at the required height while not cutting coal.
β€’     Bottom Cutting Overshoot – Is the distance the solenoid is de-energised from the floor to ensure the
      cutter stops at the required height while cutting coal.
β€’     Bottom Air Overshoot – Is the distance the solenoid is de-energised from the roof to ensure the cutter
      stops at the required height while not cutting coal.
β€’     Inclinometer Filter – provides a filter on the readings coming from the inclinometer to ensure the
      readings do not jump around too much.


December 2009                            Page 33 of 45                       Manual No. M01342

--- Page 17 ---
BI620101


                                                                               Bucyrus Australia


                             Delta SBD 30MB3 Electrical Technical Manual


Parameters – Commissioning January 2010
Parameters in Red Won’t Change at commissioning. Black parameters may change.

Setup – Left Traction         Page 102

SPEED 1:                           35%        RAMP DELTA:                          0.2s

SPEED 2:                           65%        SUMP DELTA                           0.2s

SPEED 3:                           100%       MIN SUMP:                            10%

                                              MAX SUMP:                            30%


Setup – Right Traction Page 103

SPEED 1:                           35%        RAMP DELTA:                          0.2s

SPEED 2:                           65%        SUMP DELTA                           0.2s

SPEED 3:                           100%       MIN SUMP:                            10%

                                              MAX SUMP:                            30%


Setup – Timers          Page 104

PUMP PRE START                     3 Sec       BRAKE PRESSURE DELAY                 6 Sec

CUTTER PRE START                   1 Sec       BRAKE DELAY TO APPLYING              200 ms

CONV.FWD PRE START                 1 Sec       CONV E/W PRE START TIMER             3 Sec

                                               INSTANTANEOUS OVERLOAD
CONV REV PRE START                 4 Sec                                           1200ms
                                               TIMER

MODE CHANGE PRE START              2 Sec       UNDER VOLTAGE COIL FITTED             YES


December 2009                          Page 43 of 45                       Manual No. M01342

--- Page 19 ---
BI620101


                                30MB3 MINER FAULT DISPLAY GUIDE                                                                    DELTA SBD

      MESSAGE DISPLAY                  EXPLANATION                           POSSIBLE SYMPTOM                              CHECKS TO CARRY OUT


LEFT CUTTER RTD OPEN      Motors have been stopped due to               No water supply.                     1. Ensure sufficient mine water supply.
                          excessive heat in the windings.               Blocked bag filter.                  2. Check operation of bag filter
RIGHT CUTTER RTD OPEN
                          An open circuit RTD circuit will result in    Blocked sprays.                      3. Check sprays
LEFT PUMP RTD OPEN        a reading of greater than 160 deg C. If
                                                                        Faulty motor cooling circuit.        4. Check motor cooling circuit for:
                          this occurs a message will be displayed
RIGHT PUMP RTD OPEN       and the fault logged.                         Faulty water solenoid                   c) Sufficient flow (no blockages).
LEFT GATHERER RTD OPEN    As there is a normally closed back up         Faulty pilot operated water valves      d) Damaged or broken hosing
RIGHT GATHERER RTD OPEN   thermostat in series with the RTD a           Open circuit fault in the motor      5. Check continuity of motor RTD circuit.
                          temperature trip will result in an open       RTD circuit.                         6. Check operation of water solenoid and pilot operated
LEFT CONVEYOR RTD OPEN    circuit.                                                                              water valves.
                                                                        Cable damage
RIGHT CONVEYOR RTD TRIP   NOTE: The RTD over temperature                                                     7. Check pilot cores in motor supply cable. If pilot cores
                          protection will trip the motor circuit when                                           are damaged replace cable. Motor cables have one
LEFT TRACTION RTD OPEN    a temperature of 130oC is reached.                                                    spare core.
RIGHT TRACTION RTD OPEN   The trip point of the motor thermostat is
TRANSFORMER RTD OPEN      set at 145oC.
L0LE1 RELAY OUTPUT        Each I/O module relay output has two          Loss of control voltage or open      1. Check I/O monitor page 15 to confirm faulty output
ACTIVATION FAULT          relays in series.                             circuit wiring to output relay(s)       relay and check continuity of supply wiring to I/O
L0LE2 RELAY OUTPUT        Relay 1 is to be energised and feedback       whilst activated.                       module output relays.
ACTIVATION FAULT          checked 100mS before relay 2 is closed.       Open circuit wiring between          2. Check wiring from I/O output plug (A9 or B9) to
                          If a feedback from either relay is            output relay and contactor coil.        contactor coils.
                                                                                                                                                                 o
                          detected when not required, the pumps         Open circuit wiring from contactor   3. Check wiring of contactor coil neutrals (wire N 110)
                          will shut down.                               coil to control neutral supply.      4. Check continuity of wire No 110 to neutral reference
                          If a feedback from either relay is not        Open circuit control neutral            for output relay groups.
                          detected when required the pumps will         reference to I/O module output       5. Check continuity of contactor coils.
                          be shut down.                                 relay groups.
                                                                                                             6. If the only the right pump will start in mining mode
                          Note: LOLE1 is I/O module A, and              Open circuit contactor coil.            and both pumps will start in bolting mode check the
                          LOLE2 is I/O module B.                        Faulty auxiliary contact block on       auxiliary contact block on the right pump contactor
                                                                        right pump contactor.                   (wire No116 and 125). This ensures that the other
                                                                        Internal I/O module fault               motors will not start until the right pump motor has
                                                                                                                started.
                                                                                                             7. Replace I/O module if no other faults can be found.


Manual No. M01342                                                         Page 9 of 34                                                        December 2009

--- Page 20 ---
BI620101


                                 30MB3 MINER FAULT DISPLAY GUIDE                                                                  DELTA SBD

      MESSAGE DISPLAY                   EXPLANATION                           POSSIBLE SYMPTOM                             CHECKS TO CARRY OUT


                                                                                                                module with function not operated: 600 to
                                                                                                                650mVDC. Measured from Proximity return to 0 V
                                                                                                                I.S.
                                                                                                                Return supply from proximity switch to Solenoid I/O
                                                                                                                module with function operated: 2.0 to 2.55 V I.S.
                                                                                                                Measured from Proximity return to 0 V I.S.
                                                                                                                Remove proximity switch wiring from the terminal
                                                                                                                and test continuity between the supply leads with a
                                                                                                                meter on diode range. A reading of approx 1.3 V
                                                                                                                from the positive to negative leads.
                                                                                                                If a proximity function is not working correctly
                                                                                                                perform the tests as above.
                                                                                                                A readjustment may be necessary. Unscrew the
                                                                                                                proximity until the reading goes above 2.0 V. Screw
                                                                                                                the proximity switch back in until the measured
                                                                                                                voltage reads between 600 to 650 mV. Test function
                                                                                                                for correct operation.
                                                                                                             6. Replace Solenoid I/O module if no other faults can
                                                                                                                be found.
PROXIMITY FROZEN - SHEAR   Intrinsically Safe Proximity switches are      Incorrect main spool adjustment.   1. Operate the Miner and observe the pressure gauges
UP/DOWN SOLENOIDS          fitted to the hydraulic valve bank to          Hydraulic spool jammed on             to ensure that the hydraulic system is operating
PROXIMITY FROZEN -         monitor for stuck spools, incorrect            (Hydraulic oil contamination).        correctly. Pilot pressure should be set at 35 bar.
STABILIZER UP/DOWN         operation of solenoids and valves.                                                   Check valve banks if hydraulic function operates in
                                                                          Hydraulic pilot pressure
SOLENOIDS                  The radio system monitors the status of        blockage.                             pendant mode. The brake solenoid is the only
PROXIMITY FROZEN -         the 12V I.S. Solenoid Proximity switches                                             solenoid function operated in pendant mode. All
                                                                          Solenoid valve not operating
CONVEYOR UP/DOWN           via inputs into the I.S. Solenoid Driver                                             other solenoid functions should not operate. If any
                                                                          correctly (stuck on).
SOLENOIDS                  Module.                                                                              other function operates inspect valve banks for
                                                                          Solenoid valve being operated         mechanical malfunction.
PROXIMITY FROZEN -         The pump motor operation will be
                           inhibited if the status of the spools is not   Manually.                          2. Access the Solenoid I/O monitor page 202 and
CONVEYOR LEFT/RIGHT
SOLENOIDS                  in accordance to the hydraulic operation.                                            perform a solenoid test to confirm a faulty solenoid
                           The hydraulic spool for the selected                                                 or wiring.
PROXIMITY FROZEN - PLOW
                           function has not returned to the OFF or                                           3. If the fault occurs on individual solenoids check both
IN/OUT SOLENOIDS
                           neutral position (stuck on) after                                                    active and common wiring from Solenoid output plug
PROXIMITY FROZEN - DRUM    operation when required by the control                                               (A18) to the individual solenoids.
IN/OUT SOLENOIDS           system for the β€œPROXIMITY FROZEN”
                                                                                                             4. Check operation of solenoid coils. A red LED should
PROXIMITY FROZEN - APRON   fault to occur.
Manual No. M01342                                                          Page 19 of 34                                                      December 2009

--- Page 21 ---
BI620101


Bucyrus Australia


                                  Delta SBD 30MB3 Electrical Technical Manual


Proximity Switch Install/Adjust Procedure

Installation of New Proximity - For adjustment only go to Step 5

Step 1 – Preparation

Before screwing proximity switch into the valve bank position locknut up towards the flattened section of the
thread. This will keep it out the way when screwing in. See Figure 1

View the complete manual on HeyDownloads β†’